A Large Dynamic Range Gamma Radiation Detector Insensitive to Neutron Radiation

  • A photon detector is composed of CeF3 (Cerium Fluoride) scintiplator and high current photomultipler tube (PMT). The experiment results indicate that the sensitivity of this detector is about 0.6 and 0.1 with respect to that of usual plastic scintillator ST 401, for 60Co γ and pulse DT neutron radiation, respectively. The biggest linear current of this detector is above 1.5 A, dark current is lower than 10nA. This kind of detectors is gamma pulse radiation detectors insensitive to neutron radiation with large dynamic range.
  • 加载中
  • [1] . WU Jian,XU Tong,LI Cheng et al.High Energy Phys.and Nucl.Phys.,1998,22(6):481(in Chinese)(伍健,许彤,李澄等.高能物理与核物理,1998,22(6):481) 2. ZHAO GuangJun,XU Jun.Journal of Synthetic Crys Aols,2002,31(3):291—293(in Chinese)(赵广军,徐军.人工晶体学报,2002,31(3):291—293) 3. XUE HongBin.Radiation Protection,2002,22(2):70(in Chinese)(薛红彬.辐射防护,2002,22(2):70)4. WU Chong,LI Cheng,WANG ZhaoMin et al.High Energy Phys.and Nucl. Phys.1999,23(12):1141(in Chinese)(吴冲,李澄,汪兆民等.高能物理与核物理,1999,23(12):1141) 5. WANG ZhaoMin,Xu ZiZong, GONG ZhuFang et al.Chinese Journal of Atomic and Molecular Phys.,1998,15(2):234(in Chinese)(汪兆民,许咨宗,宫竹芳等.原子与分子物理学报,1998,15(2):234) 6. Anderson D F .IEEE Transactionon Nuclear Science,1989,36:137 7. Moses W W ,Dernenzo S E .IEEE Transaction on Nuclear Science,1989,36:173 8. Alibikov A .Pulse Ionization Radiation Detector.Beijing:Atomic Energy Press,1983.7(in Chinese)(A .阿利比科夫.脉冲电离辐射探测器.北京:原子能出版社,1983.7) 9. LIU QingZhao.The Diagnosis Technology of Pulse Radiation Field.Beijing:Science Press,1994.141—149(in Chinese)(刘庆兆.脉冲辐射场诊断技术.北京:科学出版社,1994.141—149) 10. XI ChangSong.Handbook of Nuclear Radiation Detectors Their Experiment Techniques[M].Beijing:Atomic Energy Press,1990.379—383(in Chinese)(汲长松.核辐射探测器及其实验技术手册[M].北京:原子能出版社,1990.379—383)
  • 加载中

Get Citation
HU Meng-Chun, YE Wen-Ying, PENG Tai-Ping, ZHOU Dian-Zhong, WANG Zhen-Tong, ZHANG Jian-Hua, HU Qing-Yuan and YANG Hong-Qiong. A Large Dynamic Range Gamma Radiation Detector Insensitive to Neutron Radiation[J]. Chinese Physics C, 2003, 27(4): 354-358.
HU Meng-Chun, YE Wen-Ying, PENG Tai-Ping, ZHOU Dian-Zhong, WANG Zhen-Tong, ZHANG Jian-Hua, HU Qing-Yuan and YANG Hong-Qiong. A Large Dynamic Range Gamma Radiation Detector Insensitive to Neutron Radiation[J]. Chinese Physics C, 2003, 27(4): 354-358. shu
Milestone
Received: 2002-07-17
Revised: 1900-01-01
Article Metric

Article Views(2394)
PDF Downloads(614)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

A Large Dynamic Range Gamma Radiation Detector Insensitive to Neutron Radiation

    Corresponding author: HU Meng-Chun,
  • China Academy of Engineering Physics Institute of Nuclear Physics and Chemistry, Mianyang 621900, China2 China Academy of Engineering Physics Institute of Electronic Engineering, Mianyang 621900, China

Abstract: A photon detector is composed of CeF3 (Cerium Fluoride) scintiplator and high current photomultipler tube (PMT). The experiment results indicate that the sensitivity of this detector is about 0.6 and 0.1 with respect to that of usual plastic scintillator ST 401, for 60Co γ and pulse DT neutron radiation, respectively. The biggest linear current of this detector is above 1.5 A, dark current is lower than 10nA. This kind of detectors is gamma pulse radiation detectors insensitive to neutron radiation with large dynamic range.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return