Abstract:
In this paper the first results of the new ECR source at the KVI are presented. The source has been built following the design of Jyvaskyla University, which is based on the AECR-U of LBNL. As the commissioning is going on, it seems that the extraction and analysing systems inherited from the old source are the limiting factors for the performance of the new source. Beam currents achieved with the source are at the moment a factor of 3 lower than the AECR source used at the Jyvaskyla University. Further modifications to improve the source performance will be discussed.
-
-
References
[1]
|
. XIE Z Q, Lyneis C M. Rev. Sci. Instr., 1994, 65: 29472. Kremers H R et al. Proceedings of the 16th International Workshop on ECR Ion Sources, edited by M. Leitner(Berkely, 2004), p. 1753. Kremers H R et al. Rev. Sci. Instrum., 2006, 77: 3114. Koivisto H et al. Nucl Instr. and Meth. In Phys. Res., 2001,B174: 379-3845. Langmuir I. Phys. Rev., 1913, 2: 450-486 |
-
[1] |
A.G.Drentje
. Gas-mixing: Ion Cooling or Reduced Turbulent Heating?. Chinese Physics C,
2007, 31(S1): 162-164. |
[2] |
LIU Chang-Long
, LU Yi-Ying
, YIN LI
. Effects of Additional Vacancy-Like Defects Produced by Ion Impealations on Boron Thermal Diffusion in Silicon. Chinese Physics C,
2005, 29(11): 1107-1111. |
[3] |
WU Zhong-Li
. ANALYSIS OF THE MOMENTUM DISTRIBUTION WIDTH OF THE PREOJECTILE-LIKE-FRAGMENT FROM HEAVY ION COLLISIONS. Chinese Physics C,
1989, 13(8): 752-754. |
-
Access
-
-