A Two-Dimensional Poeition Sensitive Multi-Stage Detection System with a Wide Dynamic Range for Heavy Ion Reaction

  • A two-dimensional position sensitive multi-stage detection system with a wide dynamic range for heavy ion reaction has been developed. It consists of four parts: a gas filled axial ionization chamber(IC), a position sensitive silicon detector(PSSD)(45×45)mm, 400μm), a large area PIN silicon photodiode(SPD) ((48×48)mm, 300μm) and the 16 element CsI(Tl) scintillation detector. The energy resolutions for IC and PSSD tested with α-source of 241Am (5.486MeV) were 3% and 2.6% respectively. Fragments with Z values from Z=2 to Z=21 were identified in the reaction of 25MeV /u 40Ar+115In. The Z resolving power was Z/△Z≈44.5(FWHM) for Z=18. The position resolution of PSSD was (0.86± 0.03)mm (FWHM).And the energy dynamic range for a particles was about 2-130MeV.
  • 加载中
  • [1] L.Campajola et al,Nucl Instr.and Meth.,A342(1994)534.[2] LIon et al,Nucl Instr and Meth,A325(1993)458.[3] G.Prete et al,Nucl Instr and meth.,A315(1992)109.[4]郭忠言等,T R4终端高性能探测系统,高能物理与核物理,19(1995)865.[5] C.R.Cruhn et al.,Nucl Instr.and Instr.and meth.,196(1982)33.[6] H.W.Fulbright,Nucl Instr.and Meth.,162(1979)21.[7]王金川等,核电子学与探测技术,14(1994)135.[8] Zhan Wenlong et al,Radioactive Ion Beamsat H IR FL,Nucl Phys,to be published.
  • 加载中

Get Citation
Wang Jinchuan, Zhan Wenlong, Guo Zhongyan, Xi Hongfei, Zhou Jianqun, Zhao Yondong, Lei Huaihong and Luo Yongfeng. A Two-Dimensional Poeition Sensitive Multi-Stage Detection System with a Wide Dynamic Range for Heavy Ion Reaction[J]. Chinese Physics C, 1996, 20(3): 204-210.
Wang Jinchuan, Zhan Wenlong, Guo Zhongyan, Xi Hongfei, Zhou Jianqun, Zhao Yondong, Lei Huaihong and Luo Yongfeng. A Two-Dimensional Poeition Sensitive Multi-Stage Detection System with a Wide Dynamic Range for Heavy Ion Reaction[J]. Chinese Physics C, 1996, 20(3): 204-210. shu
Milestone
Received: 1900-01-01
Revised: 1900-01-01
Article Metric

Article Views(3549)
PDF Downloads(514)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

A Two-Dimensional Poeition Sensitive Multi-Stage Detection System with a Wide Dynamic Range for Heavy Ion Reaction

    Corresponding author: Wang Jinchuan,
  • Institute of Modem Physics, The Chinese Academy of Sciences, Lanzhou 730000

Abstract: A two-dimensional position sensitive multi-stage detection system with a wide dynamic range for heavy ion reaction has been developed. It consists of four parts: a gas filled axial ionization chamber(IC), a position sensitive silicon detector(PSSD)(45×45)mm, 400μm), a large area PIN silicon photodiode(SPD) ((48×48)mm, 300μm) and the 16 element CsI(Tl) scintillation detector. The energy resolutions for IC and PSSD tested with α-source of 241Am (5.486MeV) were 3% and 2.6% respectively. Fragments with Z values from Z=2 to Z=21 were identified in the reaction of 25MeV /u 40Ar+115In. The Z resolving power was Z/△Z≈44.5(FWHM) for Z=18. The position resolution of PSSD was (0.86± 0.03)mm (FWHM).And the energy dynamic range for a particles was about 2-130MeV.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return