A Two-Dimensional Poeition Sensitive Multi-Stage Detection System with a Wide Dynamic Range for Heavy Ion Reaction
- Received Date: 1900-01-01
- Accepted Date: 1900-01-01
- Available Online: 1996-03-05
Abstract: A two-dimensional position sensitive multi-stage detection system with a wide dynamic range for heavy ion reaction has been developed. It consists of four parts: a gas filled axial ionization chamber(IC), a position sensitive silicon detector(PSSD)(45×45)mm, 400μm), a large area PIN silicon photodiode(SPD) ((48×48)mm, 300μm) and the 16 element CsI(Tl) scintillation detector. The energy resolutions for IC and PSSD tested with α-source of 241Am (5.486MeV) were 3% and 2.6% respectively. Fragments with Z values from Z=2 to Z=21 were identified in the reaction of 25MeV /u 40Ar+115In. The Z resolving power was Z/△Z≈44.5(FWHM) for Z=18. The position resolution of PSSD was (0.86± 0.03)mm (FWHM).And the energy dynamic range for a particles was about 2-130MeV.