CALCULATION OF THE ELECTRIC FIELD OF A MULTIWIRE DRIFT CHAMBER
- Received Date: 1900-01-01
- Accepted Date: 1900-01-01
- Available Online: 1986-10-05
Abstract:
The matrix cap acity method used for the calculation of the electric field and the choice of the optimum voltages of the wires of the drift chamber used on the Beijing spectro-meter (BES) is described.