Design and Performance Measurement of the 1GeV/c Multiparticle Magnetic Spectrometer in the BEPC-LINAC Test Beam

  • The 2Q2D magnetic spectrometer operating at the BEPC-Linac test beam site consists of 2 quadrupole magnets,2 dipoles and 2 position sensitive detectors.The spectrometer has a maximum acceptance of solid angle 5×10-4sr,a momentum range 0.2—1.3gev/c.Beam cross section and momentum spectra have been measured on the focal plane.A reference method for momentum measurement based on the TOF difference of proton and electron is introduced.
  • 加载中
  • [1] . SHIBATA T A, KOBAYASHI T, NOMAO T et al. NIM, 1981, 179:67-762. ORAM C J, WARREN J B, MARSHALL G M et al. NIM, 1981, 179:95-1033. BARBIER M, DOWELL J D, KAMUS P I P et al. NIM, 1963, 20:66-704. MA Ji-Mao, MAO Ze-Pu et al. HEPNP, 1987, 11( 4) : 441-450 (in Chinese)(马基茂,毛泽普等.高能物理与核物理,1987,11(4):441-450)5. LU Jun-Guang et al. HEPNP, 1999, 23( 6) : 505-511(in Chinese)(吕军光等.高能物理与核物理, 1999,23(6):505-511)6. DRENTJE A G, ENGE H A, KOWALSKI S B. NIM, 1974, 122:485-4907. ANDERSON E W, COLLINS G B, FISHER G P et al . NIM, 1974,122: 587-5988. BANFORD A P. The Transport of Charged Part icle Beams. Beijin:Atomic Energy Press: 1984. 188-192, 156(in Chinese)([英]A.P.班福德著.刘经之等译.带电粒子束的输运.北京:原子能出版社,1984. 188-192,156)
  • 加载中

Get Citation
LI Jia-Cai, ZHANG Liang-Sheng, HU Chun-Liang, WU Yuan-Ming, CUI Xiang-Zong, LIU Zheng-Quan, ZHANG Shao-Ping, ZHOU Bao-Qing and ZHENG Lin-Sheng. Design and Performance Measurement of the 1GeV/c Multiparticle Magnetic Spectrometer in the BEPC-LINAC Test Beam[J]. Chinese Physics C, 2005, 29(1): 55-61.
LI Jia-Cai, ZHANG Liang-Sheng, HU Chun-Liang, WU Yuan-Ming, CUI Xiang-Zong, LIU Zheng-Quan, ZHANG Shao-Ping, ZHOU Bao-Qing and ZHENG Lin-Sheng. Design and Performance Measurement of the 1GeV/c Multiparticle Magnetic Spectrometer in the BEPC-LINAC Test Beam[J]. Chinese Physics C, 2005, 29(1): 55-61. shu
Milestone
Received: 2004-04-23
Revised: 1900-01-01
Article Metric

Article Views(3580)
PDF Downloads(641)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Design and Performance Measurement of the 1GeV/c Multiparticle Magnetic Spectrometer in the BEPC-LINAC Test Beam

    Corresponding author: LI Jia-Cai,
  • Institute of High Energy Physics,CAS,Beijing 100049,China

Abstract: The 2Q2D magnetic spectrometer operating at the BEPC-Linac test beam site consists of 2 quadrupole magnets,2 dipoles and 2 position sensitive detectors.The spectrometer has a maximum acceptance of solid angle 5×10-4sr,a momentum range 0.2—1.3gev/c.Beam cross section and momentum spectra have been measured on the focal plane.A reference method for momentum measurement based on the TOF difference of proton and electron is introduced.