MEASUREMENT OF NATURAL BACKGROUND NEUTRON

  • A high sensitive neutron monitor is described in this paper. It has an approxi-mate counting rate of 20 cpm for natural background neutrons. The pulse amplituderesolution, sensitivity and directional dependence of the monitor were determined.This monitor has been used for natural background measurement in Beijing area dur-ing passed year. The yearly average dose is given and compared with the results ofKEK and CERN.
  • 加载中
  • [1] Takaehi Nakamurs and Toshiso Kosako, Nuclear. Science and Engineering 77(1981), 182-191;中村尚司, 保健物理, 16(1981), 343-354.[2] Mitauhiro MIYALIMA et al., Measurement of Stray Neutron Doaes Around KEK-PS-Facilty (1) KEK-77-17 (1977).[3] Ferenc Hajnal et al., 1970 Sea-Levei Cosmac-ray Neutron Measurements HASL"241 Physics (TID-4500).[4] 陈常茂等, 原子能科学技术, 5(1980), 606.[5] NASA TMX-3329.[6] NCRP Repert No. 45.[7] R. H. Thomas et al.,  Neutron Moxiitoring for Radiation Protection Purposes, Vol. 1, IAEA346, 330(1972).[8] G. Rau and D. Sehwenke, Enuironmental Radiation Measurements Around the 300 Gev Accele-rator Area, SPS/RA/Note/76-6.15 March 1976.
  • 加载中

Get Citation
LI JIAN-PING, CHANG WUI-KE, XIE YAN-FONG, TANG JIN-HUA and TANG E-SHENG. MEASUREMENT OF NATURAL BACKGROUND NEUTRON[J]. Chinese Physics C, 1982, 6(6): 665-670.
LI JIAN-PING, CHANG WUI-KE, XIE YAN-FONG, TANG JIN-HUA and TANG E-SHENG. MEASUREMENT OF NATURAL BACKGROUND NEUTRON[J]. Chinese Physics C, 1982, 6(6): 665-670. shu
Milestone
Received: 1981-06-22
Revised: 1900-01-01
Article Metric

Article Views(2271)
PDF Downloads(404)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

MEASUREMENT OF NATURAL BACKGROUND NEUTRON

Abstract: A high sensitive neutron monitor is described in this paper. It has an approxi-mate counting rate of 20 cpm for natural background neutrons. The pulse amplituderesolution, sensitivity and directional dependence of the monitor were determined.This monitor has been used for natural background measurement in Beijing area dur-ing passed year. The yearly average dose is given and compared with the results ofKEK and CERN.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return