Absolute Calibration of the Soft X-Ray Streak Camera Static Characteristic

  • The soft X-ray streak camera is very important detection tool for studying soft X-ray time characteristics. We have calibrated its absolute energy response in terms of X rays provided by synchrotron Radiation Source on the BSRF. The combined uncertainty of quantum efficiency of the streak camera in 100-1000 eV photon energy reagion is 23%.
  • 加载中
  • [1] . Henke B L ,Knauer J P et al.J.Appl.Phys.,1981,52(3):15092. Henke B L ,Smith J A et al.J.Appl.Phys.,1977,48(5):18523. Kauffman R L et al.An Absolutely Calibrated Soft X-Ray Streak Camera Laser Fusion Applications.UCRL-87910p6164. Kauffman R L,Medecki H et al.A Pulsed Calibration of the Soft X-Ray Streak Camera.UCRL-83095 p5355. Kauffman R L et al.Quantitative Intensity Measurements Using a Soft x-Ray Streak Camera.IEEE of QE-19(4):616—621,19836. Gary L Stradling,Attwood D T Kauffman R L et al.A Soft X-Ray Streak Camera.IEEE of QQE-19(4):604—614,19837. GUO Bao-Ping,LIU Han-Ben.High Speed Photography and Photons,1990,19(4):11(in Chinese)(郭宝平,牛憨笨.高速摄影与光子学,1990,19(4):11)8. LUI Zhi-Yan,CHANG Zheng-Hu et al.High Speed Photography and Photons,1989,18(3):22(in Chinese)(雷志远,常曾虎等.高速摄影与光子学,1989,18(3):22)9. GAO Qiu-Shi,LUI Zhi-Yan et al.High Speed Photography and Photons,1989,18(1):40(in Chinese)(高求是,雷志远等.高速摄影与光子学,1989,18(1):40)10. ZHANG Xiao-Qiou,GONG Mei-Xia et al.High Speed Photography and Photons,1989,18(2):48(in Chinese)(张小秋,龚美霞等.高速摄影与光子学,1989,18(2):48)11. ZHANG Huan-Wen.High Speed Photography and Photons,1990,19(4):70(in Chinese)(张焕文.高速摄影与光子学,1990,19(4):70)
  • 加载中

Get Citation
YI Rong-Qing, ZHENG Zhi-Jian, HU Xin, CUI Ming-Qi, ZHAO Yi-Dong and ZHU Pei-Ping. Absolute Calibration of the Soft X-Ray Streak Camera Static Characteristic[J]. Chinese Physics C, 2003, 27(5): 452-454.
YI Rong-Qing, ZHENG Zhi-Jian, HU Xin, CUI Ming-Qi, ZHAO Yi-Dong and ZHU Pei-Ping. Absolute Calibration of the Soft X-Ray Streak Camera Static Characteristic[J]. Chinese Physics C, 2003, 27(5): 452-454. shu
Milestone
Received: 2002-07-02
Revised: 1900-01-01
Article Metric

Article Views(4169)
PDF Downloads(630)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Absolute Calibration of the Soft X-Ray Streak Camera Static Characteristic

    Corresponding author: YI Rong-Qing,
  • Institute of Nuclear Physics and Chemistry of CAEP, Laboratory for Laser Fusion, Mianyang 621900, China2 Institute of High Energy, Chinese Academy of science, Beijing 100039, China

Abstract: The soft X-ray streak camera is very important detection tool for studying soft X-ray time characteristics. We have calibrated its absolute energy response in terms of X rays provided by synchrotron Radiation Source on the BSRF. The combined uncertainty of quantum efficiency of the streak camera in 100-1000 eV photon energy reagion is 23%.