Study of Neutral Track Measurement at BES

  • The accuracy of neutral track measurement by Barrel Shower Counter (BSC) at BES is inveshgated. The photon energy in BSC is corrected using radiative Bhabha events and the error is determined. The error of photon position in BSC is also determined using the e+e process. All these results can be applied to BES analysis including neutral tracks, and the systematic error can be remarkably reduced when the kinematic fit is adopted.
  • 加载中
  • [1] BES Collab. Nucl. Instr. Math., 1994, A344:3192 Zhu Yongseng. Probability and Statistics in Experimental Physics. Beijing: Academic Press, 1991(朱永生,实验物理中的概率和统计.北京:科学出版社,1991)3 Mao Zepu et al. High Energy Phys. and Nucl. Phys. (in Chinese), 1993, 17: 193(毛泽普等,高能物理与核物理,1993,17:193) 4 Yuan C Z. BES Analysis Note, 1998, March 5 Berends F A, Gasrman K Nucl. Phys., 1973, B61:414; Harris I, Brown L M. Phys. Rev., 1957, 105: 1656;Eidelman S I, Kuraev E A. NucI. Phys., 1978, B143: 3536 Berends F A, Kleiss R NucI. Phys., 1981, B186:227 Cul X Z. BES Analysis Note, 1998, June 8 Li H B. Study of Ψ(2S)→γπ0π0 Decay, BES Analysis Note, 1998, May
  • 加载中

Get Citation
Li Haibo, Yuan Changzheng, Li Jin and Li Xinhua. Study of Neutral Track Measurement at BES[J]. Chinese Physics C, 1999, 23(7): 607-615.
Li Haibo, Yuan Changzheng, Li Jin and Li Xinhua. Study of Neutral Track Measurement at BES[J]. Chinese Physics C, 1999, 23(7): 607-615. shu
Milestone
Received: 1998-05-13
Revised: 1900-01-01
Article Metric

Article Views(3701)
PDF Downloads(609)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Study of Neutral Track Measurement at BES

    Corresponding author: Li Haibo,
  • Institute of High Energy Physics, The Chinese Academy of Sciences, Beijing 100039

Abstract: The accuracy of neutral track measurement by Barrel Shower Counter (BSC) at BES is inveshgated. The photon energy in BSC is corrected using radiative Bhabha events and the error is determined. The error of photon position in BSC is also determined using the e+e process. All these results can be applied to BES analysis including neutral tracks, and the systematic error can be remarkably reduced when the kinematic fit is adopted.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return