Status Report on Organo-metallic Beams at GANIL

  • Previous experiments with organo-metallic compounds like ferrocene, nickelocene and magnesocene showed that a pure spectrum must be obtained on the residual gas mass analyser before running successfully on the ion source. In collaboration with the chemistry department of the University of Caen, LCMT-ENSI Caen, the synthesis of these metallocene compounds has been studied to provide enriched isotopic compounds to GANIL's users. The chemical transformation yields were 90%, 80% and 43%, respectively.Vanadocene, chromocene, colbatocene and ruthenocene compounds have first been studied with a gas mass analyser and then successfully tested on the ECR 4M ion source at GANIL. Some 15eμA of 51V11+, 20eμA of 52Cr11+, 22eμA of 59Co11+, and 17eμA of 102Ru11+ were achieved. The comparison between the results obtained on the gas mass analyser and the ion beams provided by the source has allowed us to validate this method of determining whether or not an organo-metallic compound could be a candidate for running on our ECR ion source. As the ECR ion sources are tuned and used alternately on the GANIL injectors, the available time for the tests is rare, so this method could be an alternative for the validation of new compounds.
  • 加载中
  • [1] . Koivisto H et al. NIM, 1994, B94: 291-2962. Barue C et al. PHIBI Workshop, Catania, 2000. 673. Sutornin A B et al. Vestsi Akad. Navuk BSSR, Ser. Khim. Navuk, 1985, 2: 74-7 (CA- 103:142152v)4. Perevalova E G et al. Koord. Khim, 1981, 7: 1340-3 (CA-96:20210d)5. Lehérissier P et al. Rev. Sci. Instrum., 2006, 77: 03A3186. Barber W A. Inorg. Synth., 1960, 6: 117. Saito T. Chem. Commun., 1971, 22: 1422; Chernyshov EA, Reshetova M D, Rodnikov I A. Russ. J. Gen. Chem.,1980, 50: 1037-10398. Maslennikov S V, Ignatyev R A, Piskounov A V. Appl. Organometal. Chem., 2001, 15: 161-168
  • 加载中

Get Citation
P.Lehérissier1, C.Barué1, C.Canet1, M.Dubois1, M.Dupuis1, J.L.Flambard1, P.A.Jaffres2, P.Jardin1,
G.Gaubert1, N.Lecesne1, F.Lemagnen1, R.Leroy1 and J.Y.Pacquet1. Status Report on Organo-metallic Beams at GANIL[J]. Chinese Physics C, 2007, 31(S1): 85-89.
P.Lehérissier1, C.Barué1, C.Canet1, M.Dubois1, M.Dupuis1, J.L.Flambard1, P.A.Jaffres2, P.Jardin1,
G.Gaubert1, N.Lecesne1, F.Lemagnen1, R.Leroy1 and J.Y.Pacquet1. Status Report on Organo-metallic Beams at GANIL[J]. Chinese Physics C, 2007, 31(S1): 85-89. shu
Milestone
Received: 2007-05-30
Revised: 1900-01-01
Article Metric

Article Views(1224)
PDF Downloads(646)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Status Report on Organo-metallic Beams at GANIL

  • GANIL Grand Accelerateur National d'Ions Lourds, Bd H. Becquerel, BP 55027, 14076 CAEN Cedex 5, France2 ENSI CAEN-LCMT- 6 Bd Marechal Juin, 14050 CAEN Cedex, France

Abstract: Previous experiments with organo-metallic compounds like ferrocene, nickelocene and magnesocene showed that a pure spectrum must be obtained on the residual gas mass analyser before running successfully on the ion source. In collaboration with the chemistry department of the University of Caen, LCMT-ENSI Caen, the synthesis of these metallocene compounds has been studied to provide enriched isotopic compounds to GANIL's users. The chemical transformation yields were 90%, 80% and 43%, respectively.Vanadocene, chromocene, colbatocene and ruthenocene compounds have first been studied with a gas mass analyser and then successfully tested on the ECR 4M ion source at GANIL. Some 15eμA of 51V11+, 20eμA of 52Cr11+, 22eμA of 59Co11+, and 17eμA of 102Ru11+ were achieved. The comparison between the results obtained on the gas mass analyser and the ion beams provided by the source has allowed us to validate this method of determining whether or not an organo-metallic compound could be a candidate for running on our ECR ion source. As the ECR ion sources are tuned and used alternately on the GANIL injectors, the available time for the tests is rare, so this method could be an alternative for the validation of new compounds.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return