INDUCED READOUT SELF-QUENCHING STREAMER COUNTER
- Received Date: 1900-01-01
- Accepted Date: 1900-01-01
- Available Online: 1985-08-05
Abstract:
In this paper, a new technology about self-quenching streamer counter-induced readout with resistive eathode, some characteristics and preliminary results are introduced. We have investigated the influence of wire diameter, dead time on plateau curves, using different gas mixture filled in the tube (Ar/C4H10, Ar/CH4 and Ar/CO2) as basic working gas. The relations between content of various quenchers (H2C(OCH3)2, C2H5OH, C6H6 and C7H12), plateau curves and the efficiency and dead time of the tube were measured.