Abstract:
According to the storage ring injection requirements of Shanghai Synchrotron Radiation Facility (SSRF),an eddy current septum magnet prototype has been firstly constructed in China. All measured specifications of the magnet are very well satisfied with the requirements of the storage ring injection. In this article,some key issues of the design and construction of the septum magnet are discussed,the measured performances of the septum magnet are given and some constructive suggestions to improve the performance of the septum are proposed.
-
-
References
[1]
|
Lopez F, Mills F, Milton S et al. The APS Thin Pulsed Septum Magnets. 1994, Proc. 4th EPAC: 2406-24082 Rohner F. Magnetic Calculation on the Eddy Current Septum Magnet for the ESRF. 1990, ESRF Internal Note AT/MA/90-083 Kumagai K,Matsui S. IEEE Trans. Magn., 1994, 30(4): 2134-21374 Fabris R, Favari A, Tommasini D. A High Current Passive Septum Magnet for Elettra. 1992, Proc. 2nd EPAC: 1460-14625 KANG Wen, DINC Xiao-Ping, HAN Qian et al. High Energy Phys. and Nucl. Phys., 2001, 25(3): 264-270(in Chinese)(康文, 丁小平, 韩谦等. 高能物理与核物理, 2001, 25(3): 264-270)
|
-
[1] |
ZHANG Man-Zhou
, HOU Jie
, LI Hao-Hu
, LIU Gui-Min
, LI De-Ming
. Optimal sorting method and application to SSRF booster dipoles. Chinese Physics C,
2008, 32(11): 924-927.
doi: 10.1088/1674-1137/32/11/015
|
[2] |
PENG Quan-Ling
, SUN Jian
, ZHAO Guang-Yuan
, SHI Cai-Tu
. Principle and Software Design of Helmhotz Coil Measurement System. Chinese Physics C,
2001, 25(9): 920-925. |
-
Access
-
-