Invetisgation of Thermal Emittance Measurement in RF Photoinjector

  • A new method for the measurement of the thermal emittance in the RF photoinjector is introduced in the paper. The measurements are affected mainly by three factors which are the RF effect, the space charge affect and the error of measurements. According to the theory of emittance growth in the RF photoinjector and the simulation, a new method to eliminate the RF effect is proposed for the thermal emittance measurements in RF photoinjector. Error of measurements is not included , and the space charge effect is also ignored on the condition of the low charge operation mode.
  • 加载中
  • [1] .Rossbach J et al.Nucl.Instrum.Methods,1996,A375:269- 2722.TESLA Technical Design Report.March,20013.LCLS Design Study Report.Report SLAC-R-521,19984.Bonifacio R,Pellegrini C,Narducci L.Opt.Comm.,1984,50: 373-3765.Rosenweig J B,Seafini L.Phys.Rev.,1994,E50: 1599-16026.LI Zheng-Hong et al.High Power Laser and Particle Beam,2000,3:273- 275(in Chinese)(李正红等强激光与粒子束,2000,3:273-275)7.Gierman S M.Doctor Thesis,UCLA 19998.Serafini L,Rosenzweig J B.Phys.Rev.,1997,E55:7565-75909.LI Zheng-Hong.CAEP RF Photoinjecter.Mianyang:CAEP,P.H.DThesis,2000(in Chinese)(李正红.CAEP光阴极注人器.绵阳:中国工程物理研究院研究生部,博士论文,2000)10.Kim K J.Nucl.Instrum.Methods,1989,A275:201-21611.Kim K J.Nucl.Instrum.Methods,1997,A275:322-35012.Lawson J D.The Physics of Charged Particle Beams.2nd ed.New York:Oxford University Press,198813.Steffen K G.High Energy Beam Optics,DESY,196614.XING Qing-Zhi et al.HEPNP,2003,27(7):628-633(in Chinese)(邢清志等高能物理与核物理,2003,27(7):628-633)
  • 加载中

Get Citation
LI Zheng-Hong. Invetisgation of Thermal Emittance Measurement in RF Photoinjector[J]. Chinese Physics C, 2005, 29(6): 615-618.
LI Zheng-Hong. Invetisgation of Thermal Emittance Measurement in RF Photoinjector[J]. Chinese Physics C, 2005, 29(6): 615-618. shu
Milestone
Received: 2004-04-27
Revised: 1900-01-01
Article Metric

Article Views(3831)
PDF Downloads(548)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Invetisgation of Thermal Emittance Measurement in RF Photoinjector

    Corresponding author: LI Zheng-Hong,
  • Science College,South-West University of Science and Technology,MiangYang,621021 China

Abstract: A new method for the measurement of the thermal emittance in the RF photoinjector is introduced in the paper. The measurements are affected mainly by three factors which are the RF effect, the space charge affect and the error of measurements. According to the theory of emittance growth in the RF photoinjector and the simulation, a new method to eliminate the RF effect is proposed for the thermal emittance measurements in RF photoinjector. Error of measurements is not included , and the space charge effect is also ignored on the condition of the low charge operation mode.