Rem-Meter Correction Factor for Measuring High Energy Neutrons Inside Shielding

  • The dose equivalent of neutrons from intermediate energy heavy ion reactions measured with a rem-meter would be underestimated because of the energy response of the instrument. Therefore the readings of rem-meter must be corrected in order to obtain the real dose equivalent The correction factors for dose equivalent ofneutrons from the reactions of 41.7MeV/u 12C+Fe and 100MeV/u 12C+C measured inside . shielding with both rem-meters the 10 in. diameter single-sphere rem-meter and the standard A-B rem-meter have been calculated. They could be applied in dose equivalent measurement for intermediate energy heavy ion reactions.
  • 加载中
  • [1] Gabriel T A et al.ORNL-TM-4334.1975[2]Cecil R A.And erson B D,Baldwin A R etal.,Phys Rev,1981.C24:2013-2029[3]Li Guisheng.Nuclear Techniques(in Chinese),1993,16:370-376(李桂生。核技术。1993,16:370-376)[4]ICRU.Quantities and Units for Use in Radiation Protection Dosimetry.Report 51(Bethesda MD:ICRU Publications)(1993)[5]Birattari C,Ferrari A,Nuccetelli C et al.,Nucl Instr and Meth,1990,A297:250-257.[6]Patterson H W.Thomas R H,Accelerator Health Physics,New York and London,Acadcmic Press,1973,266[7]Hubbard E H;Main R M,Pyle RV.Phys,Rev,1960.118:507-514
  • 加载中

Get Citation
Li Guisheng. Rem-Meter Correction Factor for Measuring High Energy Neutrons Inside Shielding[J]. Chinese Physics C, 1998, 22(3): 283-287.
Li Guisheng. Rem-Meter Correction Factor for Measuring High Energy Neutrons Inside Shielding[J]. Chinese Physics C, 1998, 22(3): 283-287. shu
Milestone
Received: 1900-01-01
Revised: 1900-01-01
Article Metric

Article Views(2775)
PDF Downloads(566)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Rem-Meter Correction Factor for Measuring High Energy Neutrons Inside Shielding

    Corresponding author: Li Guisheng,
  • Institute of Modern Physics The Chinese Academy of Scienses, Lanzhou 730000

Abstract: The dose equivalent of neutrons from intermediate energy heavy ion reactions measured with a rem-meter would be underestimated because of the energy response of the instrument. Therefore the readings of rem-meter must be corrected in order to obtain the real dose equivalent The correction factors for dose equivalent ofneutrons from the reactions of 41.7MeV/u 12C+Fe and 100MeV/u 12C+C measured inside . shielding with both rem-meters the 10 in. diameter single-sphere rem-meter and the standard A-B rem-meter have been calculated. They could be applied in dose equivalent measurement for intermediate energy heavy ion reactions.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return