Studies on Liquid Nitrogen Cooling of Silicon Crystal Monochromator

  • There are a lot of crucial problems for beam lines design in the third generation of the synchrotron radiation source.One of the problems is high heat load.The principle,device and test results for liquid nitrogen cooling of silicon crystal monochromator are described.
  • 加载中
  • [1] Andreas K.Frund,Francois de Bergevin,Cerard Marort et al., OPTICAL ENGINEERING,29(1990)930.2 夏绍建,同步辐射光束线工程,束线光学与新技术研讨会论文集,(1995)119.3 Tetsuro Mochizuki,Xiaowei Zhang,Hirosi Sugiyana et al.Rev.Svi.Instrum,66(1995)2168.4 望月哲朗,博士论文,日本KEK,1993.
  • 加载中

Get Citation
Xia Shaojian. Studies on Liquid Nitrogen Cooling of Silicon Crystal Monochromator[J]. Chinese Physics C, 1997, 21(7): 664-667.
Xia Shaojian. Studies on Liquid Nitrogen Cooling of Silicon Crystal Monochromator[J]. Chinese Physics C, 1997, 21(7): 664-667. shu
Milestone
Received: 1900-01-01
Revised: 1900-01-01
Article Metric

Article Views(3266)
PDF Downloads(533)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Studies on Liquid Nitrogen Cooling of Silicon Crystal Monochromator

    Corresponding author: Xia Shaojian,
  • Institute of High Energy Physics,The Chinese Academy of Sciences,Beijing 100039

Abstract: There are a lot of crucial problems for beam lines design in the third generation of the synchrotron radiation source.One of the problems is high heat load.The principle,device and test results for liquid nitrogen cooling of silicon crystal monochromator are described.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return