Abstract:
More than twenty MRPC modules made of Chinese material in our Lab are tested by using cosmic rays. The test bench of cosmic rays is described in detail. The time resolution of the cosmic rays telescope is around 70ps. The time resolution of MRPC in cosmic rays testing is around 90ps. The MRPC detection efficiency,the ADC spectrum and the induced signal influence between cells are presented too.
-
-
References
[1]
|
. Cerron Zeballos E et al.Nucl.Inst . Meth.In Physics research,1996,A374:132—1352. Letter of Intent,RICE-TOF Group,Proposal for a single tray of MRPCTOF for STAR ,2001–63. HUANG ShengLi.Research on the Test System STAR-TOF’s MRPC .master thesis,Dept.of modern physics of USTC ,2001–11(in Chinese)(黄胜利.STAR -TOF的MRPC及其测量系统时间性能的研究.中国科学技术大学近代物理系硕士论文,2001,11)
|
-