Study of Sensitivity of Combination PIN Pulse Neutron Detector

  • Sensitivity of combination PIN detector was studied.The neutron sensitivity of the detector was measured and simulated by Monte-Carlo method.The detector's gamma sensitivity was measured and compared to usual PIN detector.The experiment and calculation study indicate that the neutron sensitivity of combination PIN detector can be adjusted by selecting polyethylene converter,and the detector is insensitive to gammarays.The combination PIN detector can be used to detect pulse neutron in neutron and gamma mixture radiation field.
  • 加载中
  • [1] . LIU Qing-Zhao. The Diagnosis Thecnology of Pulse Radiation Field.Beijing :Science Press ,1994. 117 (in Chinese)(刘庆兆. 脉冲辐射场诊断技术. 北京:科学出版社,1994. 117)2. MA Chi . Nuclear Electronics Detection Technology. 1995 ,15 (6) :373(in Chinese)(马驰. 核电子学与探测技术,1995 ,15(6) :373)3. Schutz R ,Fehrenbacher G,Biersack J et al . Radiation Effects Defectsin Solids ,2002 ,157 :4274. CHEN Shi-Bin , ZHANG Yi-Men ,CHEN Yu-Ming et al . High EnergyPhys. and Nucl . Phys. ,2001 ,25(4) :365 (in Chinese)(陈世彬,张义门,陈雨生等. 高能物理与核物理,2001 , 25 (4) :365)
  • 加载中

Get Citation
ZHU Xue-Bin, YANG Hong-Qiong, YANG Jian-Lun, LI Bo-Jun, YANG Gao-Zhao, LI Lin-Bo and SONG Xian-Cai. Study of Sensitivity of Combination PIN Pulse Neutron Detector[J]. Chinese Physics C, 2004, 28(9): 991-993.
ZHU Xue-Bin, YANG Hong-Qiong, YANG Jian-Lun, LI Bo-Jun, YANG Gao-Zhao, LI Lin-Bo and SONG Xian-Cai. Study of Sensitivity of Combination PIN Pulse Neutron Detector[J]. Chinese Physics C, 2004, 28(9): 991-993. shu
Milestone
Received: 2004-01-04
Revised: 1900-01-01
Article Metric

Article Views(3494)
PDF Downloads(514)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Study of Sensitivity of Combination PIN Pulse Neutron Detector

    Corresponding author: ZHU Xue-Bin,
  • Institute of Nuclear Physics and Chemistry,China Academy of Engineering Physics,Mianyang 621900,China2 Institute of Electronic Engineering,China Academy of Engineering Physics,Mianyang 621900,China

Abstract: Sensitivity of combination PIN detector was studied.The neutron sensitivity of the detector was measured and simulated by Monte-Carlo method.The detector's gamma sensitivity was measured and compared to usual PIN detector.The experiment and calculation study indicate that the neutron sensitivity of combination PIN detector can be adjusted by selecting polyethylene converter,and the detector is insensitive to gammarays.The combination PIN detector can be used to detect pulse neutron in neutron and gamma mixture radiation field.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return