CsI(Tl) Detector With Position-Sensitive Photomultiplier Readout

  • A CsI(T1) detector with a two-dimension posihonal sensitive photomultiplier readout at Radioactive Ion Beam Line in Lanzhou (RIBLL) is reported. The Cs(T1) scitillator is 10 mm in thickness and 60mm×60mm in active area. Its spatial resolution of 0.81mm (FWHM) is achieved. Finally the Monte-Carlo method is employed to simulate its spatial resolution whose result is in good agreement with the tested.
  • 加载中
  • [1] Anton G, Arends J, Beutertz W et al. Nucl. Instr. Meth., 1991, A310:631 2 Roche C T, Strauss M G, Brenner R. IEEE Trans. On Nucl. Sci., 1985, NS–32:373 3 Stelzer H. Nucl. Instr. Meth., 1991, A310: 1034 Baker O K, Beaufait J, Carlini R et al. Nucl. Instr. Meth., 1995, A367:925 Sustavov A F, Golovanv L B, Palarakin O O et al Nucl. Instr. Meth., 1995, A367: 159 6 Wang jinchuan, Zhan Wenlong, Guo Zhongyan et al. High Energy Physics and Nuclear Physics (in Chinese),1996, 22:204(王金川, 詹文龙, 郭忠言等. 高能物理与核物理, 1996,22:204)7 Garcia M R, Grinalay J E, Burg R et al. IEEE Tran. on Nucl. Sci., 1986, NS–33:7358 Antici T, Barnett B, Blumenfeld B et al. Nuc. Instr. Meth., 1995, A365:709 Bird A J, Dean A J, Grant K J. et al. Nucl. Instr. Meth., 1991, A310:323 10 Gordon J. S, McGaann W, Daley K et al. IEEE. Trans. On Nucl. Sci., 1992, NS–39:1485 11 Bird A J, He Z, Ramsdam D. Nucl. Instr. Meth., 1991, A310:33212 Haily C J. Nucl. Instr. Meth., 1989, A276:340 13 Poulsene J M, Verben R, Frontera F et al. Nucl. Instr. Meth., 1991, A310:398 14 Yasillo N J, Beck R N, Cooper M et al. IEEE. Trans. On Nucl. Sci., 1990, NS–37:609
  • 加载中

Get Citation
Qin Lijun, Zhan Wenlong, Guo Zhongyan, Xiao Guoqing, Sun Zhiyu, Li Jiaxing, Meng Xiangwei, Jiang Shanhong, Wang Jinchuan and Wang Quanjin. CsI(Tl) Detector With Position-Sensitive Photomultiplier Readout[J]. Chinese Physics C, 1999, 23(7): 629-635.
Qin Lijun, Zhan Wenlong, Guo Zhongyan, Xiao Guoqing, Sun Zhiyu, Li Jiaxing, Meng Xiangwei, Jiang Shanhong, Wang Jinchuan and Wang Quanjin. CsI(Tl) Detector With Position-Sensitive Photomultiplier Readout[J]. Chinese Physics C, 1999, 23(7): 629-635. shu
Milestone
Received: 1998-06-26
Revised: 1900-01-01
Article Metric

Article Views(5042)
PDF Downloads(581)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

CsI(Tl) Detector With Position-Sensitive Photomultiplier Readout

    Corresponding author: Qin Lijun,
  • Institute of Modern Physics, The Chinese Academy of Sciences, Lanzhou 730000

Abstract: A CsI(T1) detector with a two-dimension posihonal sensitive photomultiplier readout at Radioactive Ion Beam Line in Lanzhou (RIBLL) is reported. The Cs(T1) scitillator is 10 mm in thickness and 60mm×60mm in active area. Its spatial resolution of 0.81mm (FWHM) is achieved. Finally the Monte-Carlo method is employed to simulate its spatial resolution whose result is in good agreement with the tested.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return