Neutron Energy Response of the Combined Scintillator Detection System

  • The Combined Scintillator Detection System is compsed of Pb fiter leaf and plastic sintillator detector. Using direct current scale, the neutron sensitivity of detecion system composed of Pb fiter leaf and ST401, ST1422 and ST1423 detector,respectively has been studied at the neutron energy 0.565 MeV, 1.20 MeV, 2.50 MeV, 3.50 MeV, 5.00 MeV and 14.16 MeV. From the experiment results we get the relation of the detector's sensitivity and the thickness of Pb fiter leaf, the thickness of scintillator, and the neutrons energy. By the experiment and calculation the neutron energy response of three kinds of combined scintillator detection system is obtained.
  • 加载中
  • [1] . LIU Qing-Zhao. The Diagnosis Technology of Pulse Radiation Filed.Beijing: Science Press, 1994. 524-536(in Chinese)(刘庆兆.脉冲辐射场诊断技术.北京:科学出版社,1994. 524-536)2. SHEN Guan-Ren,TANG Hong-Qing, YU Chun-Ying et al. Atomic En-ergy Science and Technology, 1992, 26(1) : 26-30(in Chinese)(沈冠仁,唐洪庆,于春英等.原子能科学技术,1992,26(1):26-30)3. YANG Hong-Qiong, ZHU Xue-Bin, PENG Tai-Ping et al . HEPNP,2004, 28( 7) : 744 - 748(in Chinese)(杨洪琼,朱学彬,彭太平等.高能物理与核物理,2004,28(7):744-748)4. ZHU Xue-Bin, YANG Hong-Qiong, YANG Jian-Lun et al. HEPNP,2004. 28( 9) : 991- 993(in Chinese)(朱学彬,杨洪琼,杨建伦等.高能物理与核物理,2004,28(9):991-993)5. DING Sheng-Yue,HAN Kui-Chu. Trends in Nuclear Physics. 1994, 11( 2) : 65 -67(in Chinese)(丁声跃,韩奎初.核物理动态.1994,11(2):65-67)6. YANG Jian-Lun, PENG Xian-Jue, YANG Hong-Qiong et al. Nuclear Electronica Detect ion Technology , 2004, 24(4) : 346 - 349(in Chinese)(杨建伦,彭先觉,杨洪琼等.核电子学与探测技术,2004, 24(4):346-349)
  • 加载中

Get Citation
YANG Hong-Qiong, PENG Dai-Ping, YANG Jian-Lun, TANG Zheng-Yuan, YANG Gao-Zhao, LI Lin-Bo, WANG Li-Zong and ZHU Xue-Bin. Neutron Energy Response of the Combined Scintillator Detection System[J]. Chinese Physics C, 2005, 29(7): 691-694.
YANG Hong-Qiong, PENG Dai-Ping, YANG Jian-Lun, TANG Zheng-Yuan, YANG Gao-Zhao, LI Lin-Bo, WANG Li-Zong and ZHU Xue-Bin. Neutron Energy Response of the Combined Scintillator Detection System[J]. Chinese Physics C, 2005, 29(7): 691-694. shu
Milestone
Received: 2004-11-09
Revised: 1900-01-01
Article Metric

Article Views(5050)
PDF Downloads(615)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Neutron Energy Response of the Combined Scintillator Detection System

    Corresponding author: YANG Hong-Qiong,
  • Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics,Mianyang 621900,China

Abstract: The Combined Scintillator Detection System is compsed of Pb fiter leaf and plastic sintillator detector. Using direct current scale, the neutron sensitivity of detecion system composed of Pb fiter leaf and ST401, ST1422 and ST1423 detector,respectively has been studied at the neutron energy 0.565 MeV, 1.20 MeV, 2.50 MeV, 3.50 MeV, 5.00 MeV and 14.16 MeV. From the experiment results we get the relation of the detector's sensitivity and the thickness of Pb fiter leaf, the thickness of scintillator, and the neutrons energy. By the experiment and calculation the neutron energy response of three kinds of combined scintillator detection system is obtained.