Experimental comparison of various techniques for spot size measurement of high-energy X-ray sources

  • In flash-radiography experiments, the quality of the acquired image strongly depends on the focal size of the X-ray source spot. A variety of techniques based on imaging of the pinhole, the slit and the rollbar are adopted to measure the focal spot size of the Dragon-I linear induction accelerator. The image of the pinhole provides a two-dimensional distribution of the X-ray spot, while those of the slit and the rollbar give a line-spread distribution and an edge-spread distribution, respectively. The spot size characterized by the full-width at half-maximum and that characterized by the LANL definition are calculated for comparison.
      PCAS:
  • 加载中
  • [1] T. J. Boyd, Jr., B. T. Rogers, R. R. Tesche and Douglas Venable, Rev. Sci. Instrum. 36, 1401-1408 (1965)
    [2] T. J. Fessenden, W. L. Atchison, D. L. Birx, J. C. Clark, E. G. Cook, R. E. Hester, L. L. Reginato, D. Rogers, R. E. Spoerlein, K. W. Struve and T. T. Yokota, IEEE Transactions on Nuclear Science NS, 28(3), 3401-3403 (1981)
    [3] M. Burns, P. Allison, J. Downing, D. Moir, G. Caporaso and Y. J. Chen, 9th International Conference on High-Power Particle Beams, Beams 92(1): 283-290 (1992)
    [4] Y. J. Chen, D. Dalmas, G. Durtschi et. al., IEEE Transactions on Plasma Science, 33(2), 892-900 (2005)
    [5] J. J. Deng, B. N. Ding, H. C. Wang, G. S. Dai, N. A. Cheng, L. W. Zhang, K. Z. Zhang, Z. Y. Dai and J. S. Shi, High Power Laser and Particle Beams, 15(5): 502-504 (2003)
    [6] S. Nath, Proceedings of Linear Accelerator Conference LINAC2010, Tsukuba, Japan, 2010
    [7] M. Gambaccini, P. Cardarelli, A. Taibi, A. Franconieri, G. D. Domenico, M. Marziani, R. C. Barna, L. Auditore, E. Morgana, D. Loria, A. Trifiro and M. Trimarchi, Nuclear Instruments and Methods in Physics Research B, 269(10): 1157-1165 (2011)
    [8] R. A. Richardson and T. L. Houck, Proceedigs Of the XIX Iterational Linac Conference, Chicago, Illinois, U.S.A. 1998
    [9] K. H. Muller, Los Alamos National Laboratory Report LA-UR-89-1886, August 1989
    [10] D. W. Forster, AWE Report HWH/9201/R8 (January 1992)
    [11] C. Ekdahl, Journal of the Optical Society of America A, 28(12): 2501-2509 (2011)
  • 加载中

Get Citation
Yi Wang, Qin Li, Nan Chen, Jin-Ming Cheng, Cheng-Gang Li, Hong Li, Quan-Hong Long, Jin-Shui Shi and Jian-Jun Deng. Experimental comparison of various techniques for spot size measurement of high-energy X-ray sources[J]. Chinese Physics C, 2016, 40(8): 086205. doi: 10.1088/1674-1137/40/8/086205
Yi Wang, Qin Li, Nan Chen, Jin-Ming Cheng, Cheng-Gang Li, Hong Li, Quan-Hong Long, Jin-Shui Shi and Jian-Jun Deng. Experimental comparison of various techniques for spot size measurement of high-energy X-ray sources[J]. Chinese Physics C, 2016, 40(8): 086205.  doi: 10.1088/1674-1137/40/8/086205 shu
Milestone
Received: 2015-11-30
Article Metric

Article Views(2948)
PDF Downloads(138)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Experimental comparison of various techniques for spot size measurement of high-energy X-ray sources

    Corresponding author: Yi Wang,
  • 1. Key Laboratory of Pulsed Power, Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, Sichuan Province, China

Abstract: In flash-radiography experiments, the quality of the acquired image strongly depends on the focal size of the X-ray source spot. A variety of techniques based on imaging of the pinhole, the slit and the rollbar are adopted to measure the focal spot size of the Dragon-I linear induction accelerator. The image of the pinhole provides a two-dimensional distribution of the X-ray spot, while those of the slit and the rollbar give a line-spread distribution and an edge-spread distribution, respectively. The spot size characterized by the full-width at half-maximum and that characterized by the LANL definition are calculated for comparison.

    HTML

Reference (11)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return