-
Abstract:
The project of a 10 MeV PET cyclotron accelerator for medical diagnosis and treatment was started at Amirkabir University of Technology in 2012. The low-level RF system of the cyclotron accelerator is designed to stabilize acceleration voltage and control the resonance frequency of the cavity. In this work an Intelligent Low Level Radio Frequency Circuit or ILLRF, suitable for most AVF cyclotron accelerators, is designed using a beam monitoring device and narrow band tunable band-pass filter. In this design, the RF phase detection does not need signal processing by a microcontroller.
-
-
References
[1]
|
K Liu et al, Proc. of IPAC, particle accelerator, San Sebastian, Spain,(2011) 1753 |
[2]
|
S Turner, CAS-CERN Accelerator School,(1992) 437 |
[3]
|
Analog Devices:AD9859 Datasheet, Analog Devices, Inc.(2009) 24 |
[4]
|
A Caruso et al, Proc. of CYCLOTRONS, Lanzhou, China,(2010) 159 |
[5]
|
P Li et al, Nucl. Instrum. Methods A, 735:184(2014) |
[6]
|
Analog Devices:AD8302 Datasheet, Analog Devices, Inc.(2002) 24 |
[7]
|
X Wang et al, Nucl. Instrum. Meth B,(2007) 26 |
[8]
|
S Hojo et al, in:IBIC 2012, Tsukuba, Japan,(2012) 60 |
[9]
|
E Mazur, The Principles and Practice of Physics, CHAPTER 28,(2014) |
[10]
|
Analog Devices:AD8367 Datasheet, Analog Devices, Inc.(2001) 16. |
[11]
|
Analog Devices:AD8361 Datasheet, Analog Devices, Inc.(2004) 16. |
[12]
|
Analog Devices:AD736 Datasheet. Analog Devices, Inc.(2012) 20. |
[13]
|
Wang C, 3rd International Design and Test Workshop, IDT 354:357(2008) |
[14]
|
Texas Instruments:SN74HC148 Datasheet,(2004) |
-
[1] |
ZHANG Zhou-Li
, HE Yuan
, ZHANG Bin
, LI De-Run
, SHI Ai-Min
, PAN Gang
, DU Xiao-Nan
, SUN Lie-Peng
. Study of influence of radial matcher section end shape on RFQ cavity frequency. Chinese Physics C,
2014, 38(7): 077007.
doi: 10.1088/1674-1137/38/7/077007
|
[2] |
DU Ying-Shuai
, YUE Qian
, LIU Yi-Bao
, CHEN Qing-Hao
, LI Jin
, CHENG Jian-Ping
, KANG Ke-Jun
, LI Yuan-Jing
, LI Yu-Lan
, MA Hao
, XING Hao-Yang
, YU Xun-Zhen
, ZENG Zhi
. Characterization of large area photomultiplier ETL 9357FLB for liquid argon detector. Chinese Physics C,
2014, 38(7): 076003.
doi: 10.1088/1674-1137/38/7/076003
|
[3] |
HUANG Jiang
, XIONG Yong-Qian
, CHEN De-Zhi
, LIU Kai-Feng
, YANG Jun
, LI Dong
, YU Tiao-Qin
, FAN Ming-Wu
, YANG Bo
. A permanent magnet electron beam spread system used fora low energy electron irradiation accelerator. Chinese Physics C,
2014, 38(10): 107008.
doi: 10.1088/1674-1137/38/10/107008
|
[4] |
M. Bashkanov (for the WASA-at-COSY collaboration)
. ABC effect in double-pionic nuclear fusion and a pn resonance as its possible origin. Chinese Physics C,
2010, 34(9): 1339-1341.
doi: 10.1088/1674-1137/34/9/037
|
[5] |
ZHOU Yong-Zhao
, LIANG Hao
, XUE Jun-Dong
, CHEN Yi-Xin
, YANG Tao
, GONG Da-Tao
, JIN Ge
, YU Xiao-Qi
. An Online Program for Monitoring KLOE Experiment. Chinese Physics C,
2002, 26(6): 620-625. |
[6] |
BES Collaboration
. Experimental Study of Resonance f2(1270) in the J/ψ Hadronic Decay. Chinese Physics C,
1993, 17(2): 97-106. |
[7] |
WANG Man
, LI Jin
, CUI Xiang-Zong
, XIA Xiao-Mi
, LAI Yuan-Fen
, YAO Xiao-Guang
. PROTOTYPE OF END CAP SHOWER COUNTERAND ITS BEAM TEST. Chinese Physics C,
1987, 11(3): 321-326. |
-
Access
-
-