Optimum angle-cut of collimator for dense objects in high-energy proton radiography

  • The use of minus identity lenses with an angle-cut collimator can achieve high contrast images in high-energy proton radiography. This article presents the principles of choosing the angle-cut aperture of the collimator for different energies and objects. Numerical simulation using the Monte Carlo code Geant4 has been implemented to investigate the entire radiography for the French test object. The optimum angle-cut apertures of the collimators are also obtained for different energies.
      PCAS:
  • 加载中
  • [1] H. J. Ziock, K. J. Adams, K. R. Alrick et al,The Proton Radiography Concept, Los Alamos National Laboratory, LA-UR-98-1368 (1998)
    [2] C. L. Morris, Proton Radiography for an Advanced Hydrotest Facility, Los Alamos National Laboratory, LA-UR-00-5716 (2000)
    [3] C. L. Morris, J. W. Hopson, P. Goldstone, Proton Radiography, Los Alamos National Laboratory, LA-UR-06-0331 (2006)
    [4] C. T. Mottershead, J. D. Zumbro, Magnetic Optics for Proton Radiography, in Proceedings of the 1997 Particle Accelerator Conference (Canada: Vancouver B C, 1997), p. 1397
    [5] J. D. Zumbro, Angle-cuts for the Brookhaven Proton Radiography Experiments E955 and E963 Calculated with MCNPm TM (U), Los Alamos National Laboratory, LA-UR-05-7370 (2005)
    [6] H. B. Xu, High Power Laser and Particle Beams, 18(3): 477-482 (2006) (in Chinese)
    [7] M. B. Aufderheide, H. S. Park, E. P. Hartouni et al, Proton Radiography as a Means of Material Characterization, Lawrence Livermore National Laboratory, UCRL-JC-134595 (1999)
    [8] F. Neri, P. L. Walstrom, Nuclear Instruments and Methods in Physics Research B, 229: 425-435 (2005)
    [9] C. L. Morris, E. Ables, K. R. Alrick et al, Journal of Applied Physics, 109: 104905 (2011)
    [10] X. Z. He, G. J. Yang, C. J. Liu, High Power Laser and Particle Beams, 20(2): 297-300 (2008) (in Chinese)
    [11] H. B. Xu, N. Zheng, Chinese Physics C, 39 (7): 078201 (2015)
    [12] S. Agostinelliae, J. Allisonas, K. Amako et al, Nuclear Instruments and Methods in Physics Research A, 506: 250-303 (2003)
    [13] J. D. Zumbro, A. Acuff, J. S. Bull et al, Radiation Protection Dosimetry, 117(4): 447-452 (2005)
    [14] K. H. Muellerm, SPIE High Speed Photography, 491: 130-136 (1984)
  • 加载中

Get Citation
Hai-Bo Xu and Na Zheng. Optimum angle-cut of collimator for dense objects in high-energy proton radiography[J]. Chinese Physics C, 2016, 40(2): 028201. doi: 10.1088/1674-1137/40/2/028201
Hai-Bo Xu and Na Zheng. Optimum angle-cut of collimator for dense objects in high-energy proton radiography[J]. Chinese Physics C, 2016, 40(2): 028201.  doi: 10.1088/1674-1137/40/2/028201 shu
Milestone
Received: 2015-04-08
Revised: 2015-09-18
Fund

    Supported by NSAF (11176001) and Science and Technology Developing Foundation of China Academy of Engineering Physics (2012A0202006)

Article Metric

Article Views(3015)
PDF Downloads(121)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Optimum angle-cut of collimator for dense objects in high-energy proton radiography

    Corresponding author: Na Zheng,
  • 1. Institute of Applied Physics and Computational Mathematics, Beijing 100094, China
Fund Project:  Supported by NSAF (11176001) and Science and Technology Developing Foundation of China Academy of Engineering Physics (2012A0202006)

Abstract: The use of minus identity lenses with an angle-cut collimator can achieve high contrast images in high-energy proton radiography. This article presents the principles of choosing the angle-cut aperture of the collimator for different energies and objects. Numerical simulation using the Monte Carlo code Geant4 has been implemented to investigate the entire radiography for the French test object. The optimum angle-cut apertures of the collimators are also obtained for different energies.

    HTML

Reference (14)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return