Study of medium beta elliptical cavities for CADS
- Received Date: 2015-05-13
- Accepted Date: 2015-07-21
- Available Online: 2016-02-20
Abstract: The China Accelerator-Driven Sub-critical System (CADS) is a high intensity proton facility to dispose of nuclear waste and generate electric power. CADS is based on a 1.5 GeV, 10 mA CW superconducting (SC) linac as a driver. The high energy section of the linac is composed of two families of SC elliptical cavities which are designed with geometrical beta 0.63 and 0.82. In this paper, the 650 MHz β=0.63 SC elliptical cavity is studied, including cavity optimization, multipacting, high order modes (HOMs) and generator RF power calculation.