Abstract:
Hefei Light Source (HLS) is being upgraded to HLS Ⅱ. Its emittance will be much lower than before, therefore the Touschek scattering will increase significantly and become the dominant factor of beam loss. So it is necessary to build a new beam loss monitoring (BLM) system that, in contrast to the old one, is able to obtain the quantity and position information of lost electrons. This information is useful in the commissioning, troubleshooting, and beam lifetime studying for HLS Ⅱ. This paper analyzes the distribution features of different kinds of lost electrons, introduces the operation parameters of the new machine and discusses how to choose proper monitoring positions. Based on these comprehensive analyses, a new BLM system for HLS Ⅱ is proposed.
-
-
References
[1]
|
Bialowons W, Ridoutt F, Wittenburg K. Electron Beam Loss Monitors for HERA. in Fourth European Particle Accelerator Conference (EPAC94). World Scientific. 1994. 1628[2] LI Yu-Xiong et al. The Beam Loss Monitoring System for HLS Storage Ring. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2001, 467: 80-83[3] CUI Yong-Gang et al. Nuclear Techniques, 2002, 25(2): 95-98[4] CUI Yong-Gang et al. Nuclear Electronics and Detection Technology, 2002, 22(1): 72-77[5] ZHAO Xiao-Yan et al. Chinese Physics C (HEP NP), 2008, 32(3): 80-82[6] CAI Jun et al. Nuclear Science and Techniques, 2011, 22: 5-8[7] LI Yu-Xiong et al. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003, 505(1): 366-369[8] LI Yu-Xiong et al. A New Tool for Beam-Life Research at HLS Storage Ring. Particle Accelerator Conference, 2003. PAC 2003. Proceedings of the. Vol. 4. IEEE, 2003[9] Le Duff. Single and Multiple Touschek Effects. in Proc. of the CERN Acc. School, Berlin 1989, CERN 89-01. 114-130 |
-
[1] |
Xin Wu
, Qi Chen
, Ye Xing
, Zhi-Peng Xing
, Ruilin Zhu
. SU(3) flavor symmetry analysis of hyperon non-leptonic two body decays. Chinese Physics C,
2025, 49(12): 123101.
doi: 10.1088/1674-1137/adf1f1
|
[2] |
D. Banerjee
, S. Sahoo
. Analysis of λb→λ l+l- rare decays in a non-universal Z' model. Chinese Physics C,
2017, 41(8): 083101.
doi: 10.1088/1674-1137/41/8/083101
|
[3] |
HUANG Jiang
, XIONG Yong-Qian
, CHEN De-Zhi
, LIU Kai-Feng
, YANG Jun
, LI Dong
, YU Tiao-Qin
, FAN Ming-Wu
, YANG Bo
. A permanent magnet electron beam spread system used fora low energy electron irradiation accelerator. Chinese Physics C,
2014, 38(10): 107008.
doi: 10.1088/1674-1137/38/10/107008
|
[4] |
ZHANG Cong
, HE Yuan
, ZHAO Hong-Wei
, ZHANG Sheng-Hu
. Multipacting simulation and analysis of a taper quarter wave cavity by using Analyst-PT3P. Chinese Physics C,
2012, 36(4): 362-366.
doi: 10.1088/1674-1137/36/4/012
|
[5] |
YANG Hong-Xun (for the BESⅡ collaboration)
. Partial wave analysis of J/ψ→ppπ0 and measurement of J/ψ→ppη, ppη´. Chinese Physics C,
2009, 33(12): 1331-1335.
doi: 10.1088/1674-1137/33/12/048
|
[6] |
PENG Quan-Ling
, SUN Jian
, ZHAO Guang-Yuan
, SHI Cai-Tu
. Principle and Software Design of Helmhotz Coil Measurement System. Chinese Physics C,
2001, 25(9): 920-925. |
[7] |
ZHU Xiang
, SHEN Wen-Qing
, HU Xiao-Qing
, ZHU Yong-Tai
, WANG Bing
. A SIMPLE MODEL ANALYSIS OF THE INCOMPLETE DIC REACTION. Chinese Physics C,
1990, 14(9): 835-841. |
[8] |
WU Zhong-Li
. ANALYSIS OF THE MOMENTUM DISTRIBUTION WIDTH OF THE PREOJECTILE-LIKE-FRAGMENT FROM HEAVY ION COLLISIONS. Chinese Physics C,
1989, 13(8): 752-754. |
-
Access
-
-