Theoretical analysis of BLM system for HLS Ⅱ

  • Hefei Light Source (HLS) is being upgraded to HLS Ⅱ. Its emittance will be much lower than before, therefore the Touschek scattering will increase significantly and become the dominant factor of beam loss. So it is necessary to build a new beam loss monitoring (BLM) system that, in contrast to the old one, is able to obtain the quantity and position information of lost electrons. This information is useful in the commissioning, troubleshooting, and beam lifetime studying for HLS Ⅱ. This paper analyzes the distribution features of different kinds of lost electrons, introduces the operation parameters of the new machine and discusses how to choose proper monitoring positions. Based on these comprehensive analyses, a new BLM system for HLS Ⅱ is proposed.
      PCAS:
  • 加载中
  • [1] Bialowons W, Ridoutt F, Wittenburg K. Electron Beam Loss Monitors for HERA. in Fourth European Particle Accelerator Conference (EPAC94). World Scientific. 1994. 1628[2] LI Yu-Xiong et al. The Beam Loss Monitoring System for HLS Storage Ring. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2001, 467: 80-83[3] CUI Yong-Gang et al. Nuclear Techniques, 2002, 25(2): 95-98[4] CUI Yong-Gang et al. Nuclear Electronics and Detection Technology, 2002, 22(1): 72-77[5] ZHAO Xiao-Yan et al. Chinese Physics C (HEP NP), 2008, 32(3): 80-82[6] CAI Jun et al. Nuclear Science and Techniques, 2011, 22: 5-8[7] LI Yu-Xiong et al. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003, 505(1): 366-369[8] LI Yu-Xiong et al. A New Tool for Beam-Life Research at HLS Storage Ring. Particle Accelerator Conference, 2003. PAC 2003. Proceedings of the. Vol. 4. IEEE, 2003[9] Le Duff. Single and Multiple Touschek Effects. in Proc. of the CERN Acc. School, Berlin 1989, CERN 89-01. 114-130
  • 加载中

Get Citation
CHEN Yu-Kai, LI Yu-Xiong, LI Wei-Min and HE Li-Juan. Theoretical analysis of BLM system for HLS Ⅱ[J]. Chinese Physics C, 2015, 39(1): 017003. doi: 10.1088/1674-1137/39/1/017003
CHEN Yu-Kai, LI Yu-Xiong, LI Wei-Min and HE Li-Juan. Theoretical analysis of BLM system for HLS Ⅱ[J]. Chinese Physics C, 2015, 39(1): 017003.  doi: 10.1088/1674-1137/39/1/017003 shu
Milestone
Received: 2014-01-22
Revised: 1900-01-01
Article Metric

Article Views(3267)
PDF Downloads(195)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Theoretical analysis of BLM system for HLS Ⅱ

    Corresponding author: CHEN Yu-Kai,
    Corresponding author: LI Yu-Xiong,

Abstract: Hefei Light Source (HLS) is being upgraded to HLS Ⅱ. Its emittance will be much lower than before, therefore the Touschek scattering will increase significantly and become the dominant factor of beam loss. So it is necessary to build a new beam loss monitoring (BLM) system that, in contrast to the old one, is able to obtain the quantity and position information of lost electrons. This information is useful in the commissioning, troubleshooting, and beam lifetime studying for HLS Ⅱ. This paper analyzes the distribution features of different kinds of lost electrons, introduces the operation parameters of the new machine and discusses how to choose proper monitoring positions. Based on these comprehensive analyses, a new BLM system for HLS Ⅱ is proposed.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return