Measurements of charge transfer efficiency in a proton-irradiated swept charge device

Get Citation
WANG Yu-Sa, YANG Yan-Ji, CHEN Yong, LIU Xiao-Yan, CUI Wei-Wei, XU Yu-Peng, LI Cheng-Kui, LI Mao-Shun, HAN Da-Wei, CHEN Tian-Xiang, HUO Jia, WANG Juan, LI Wei, HU Wei, ZHANG Yi, LU Bo, YIN Guo-He, ZHU Yue and ZHANG Zi-Liang. Measurements of charge transfer efficiency in a proton-irradiated swept charge device[J]. Chinese Physics C, 2014, 38(6): 066001. doi: 10.1088/1674-1137/38/6/066001
WANG Yu-Sa, YANG Yan-Ji, CHEN Yong, LIU Xiao-Yan, CUI Wei-Wei, XU Yu-Peng, LI Cheng-Kui, LI Mao-Shun, HAN Da-Wei, CHEN Tian-Xiang, HUO Jia, WANG Juan, LI Wei, HU Wei, ZHANG Yi, LU Bo, YIN Guo-He, ZHU Yue and ZHANG Zi-Liang. Measurements of charge transfer efficiency in a proton-irradiated swept charge device[J]. Chinese Physics C, 2014, 38(6): 066001.  doi: 10.1088/1674-1137/38/6/066001 shu
Milestone
Received: 2013-08-08
Revised: 2013-12-16
Article Metric

Article Views(1917)
PDF Downloads(279)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Measurements of charge transfer efficiency in a proton-irradiated swept charge device

    Corresponding author: WANG Yu-Sa,

Abstract: Charged Coupled Devices (CCDs) have been successfully used in several low energy X-ray astronomical satellites over the past two decades. Their high energy resolution and high spatial resolution make them a perfect tool for low energy astronomy, such as observing the formation of galaxy clusters and the environment around black holes. The Low Energy X-ray Telescope (LE) group is developing a Swept Charge Device (SCD) for the Hard X-ray Modulation Telescope (HXMT) satellite. A SCD is a special low energy X-ray CCD, which can be read out a thousand times faster than traditional CCDs, simultaneously keeping excellent energy resolution. A test method for measuring the charge transfer efficiency (CTE) of a prototype SCD has been set up. Studies of the charge transfer inefficiency (CTI) with a proton-irradiated SCD have been performed at a range of operating temperatures. The SCD is irradiated by 3×108cm-2 10 MeV protons.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return