Abstract:
Diffraction enhanced imaging (DEI) has been widely applied in many fields, especially when imaging low-Z samples or when the difference in the attenuation coefficient between different regions in the sample is too small to be detected. Recent developments of this technique have presented a need for a new software package for data analysis. Here, the Diffraction Enhanced Image Reconstructor (DEIReconstructor), developed in Matlab, is presented. DEIReconstructor has a user-friendly graphical user interface and runs under any of the 32-bit or 64-bit Microsoft Windows operating systems including XP and Win7. Many of its features are integrated to support imaging preprocessing, extract absorption, refractive and scattering information of diffraction enhanced imaging and allow for parallel-beam tomography reconstruction for DEI-CT. Furthermore, many other useful functions are also implemented in order to simplify the data analysis and the presentation of results. The compiled software package is freely available.
-
-
References
[1]
|
Dilmanian F et al. Phys. Med. Biol., 2000, 45: 933[2] Wilkins S et al. Nature, 1996, 384: 335[3] Chapman D et al. Synchrotron Radiation News, 1998, 11: 4[4] Momose A, Kawamoto S. Jpn. J. Appl. Phys., 2006, 45: 314[5] Pavlov K et al. J. Phys. D: Appl. Phys., 2001, 34: 168[6] ZHU P et al. J. Phys. D: Appl. Phys., 2006, 39: 4142[7] ZHU P et al. PNAS, 2010, 107: 13576[8] ZHANG K et al. Phys. Med. Biol., 2008, 53: 5757[9] CHEN R C et al. J. Synchrotron. Radiat, 2012, 19: 836[10] Chapman D et al. Phys. Med. Biol., 1997, 42: 2015[11] ZHANG K et al. Anal. Bioanal. Chem., 2010, 397: 2067[12] ZHU P P et al. Appl. Phys. Lett., 2005, 87: 264101[13] Maksimenko A et al. Appl. Phys. Lett., 2005. 86: 1241051[14] ZHANG X et al. Phys. Med. Biol., 2008, 53: 5735[15] WANG M et al. J. Phys. D: Appl. Phys., 2007, 40: 6917[16] WANG J et al. Phys. Med. Biol., 2006, 51: 3391[17] HUANG Z et al. Appl. Phys. Lett., 2006, 89: 041124[18] SUN Y et al. Computerized Tomography Based on X-ray Refraction Information. In Biomedical Imaging: Nano to Macro, 2006. 3rd IEEE International Symposium on. 2006. 1022[19] Oltulu O et al. J. Phys. D: Appl. Phys., 2003, 17: 2152 |
-
[1] |
Ronghao Hu
, Qike Gu
, Kejian Shi
, Zezhong Wei
, Meng Lv
, Shiyang Zou
, Yongkun Ding
. Polarized neutron beams from polarized deuterium-tritium fusion with applications to magnetic field imaging in high-energy-density plasmas. Chinese Physics C,
2025, 49(12): 124102.
doi: 10.1088/1674-1137/adec4f
|
[2] |
WANG Ji-Ke
, MAO Ze-Pu
, BIAN Jian-Ming
, CAO Guo-Fu
, CAO Xue-Xiang
, CHEN Shen-Jian
, DENG Zi-Yan
, FU Cheng-Dong
, GAO Yuan-Ning
, HE Kang-Lin
, HE Miao
, HUA Chun-Fei
, HUANG Bin
, HUANG Xing-Tao
, JI Xiao-Bin
, LI Fei
, LI Hai-Bo
, LI Wei-Dong
, LIANG Yu-Tie
, LIU Chun-Xiu
, LIU Huai-Min
, LIU Suo
, LIU Ying-Jie
, MA Qiu-Mei
, MA Xiang
, MAO Ya-Jun
, MO Xiao-Hu
, PAN Ming-Hua
, PANG Cai-Ying
, PING Rong-Gang
, QIN Ya-Hong
, QIU Jin-Fa
, SUN Sheng-Sen
, SUN Yong-Zhao
, WANG Liang-Liang
, WEN Shuo-Pin
,
,
,
,
,
,
. Software alignment of the BESⅢ main drift chamber using the Kalman Filter method. Chinese Physics C,
2009, 33(3): 210-216.
doi: 10.1088/1674-1137/33/3/010
|
[3] |
PENG Quan-Ling
, SUN Jian
, ZHAO Guang-Yuan
, SHI Cai-Tu
. Principle and Software Design of Helmhotz Coil Measurement System. Chinese Physics C,
2001, 25(9): 920-925. |
-
Access
-
-