Design and cold test of a rectangular cavity beam position monitor

  • CBPM is a kind of monitor which is used for the measurement of beam transverse position. And it is more and more popular for its high potential in the resolution performance. In theory, the resolution can reach about 1 nanometer. In this paper, a rectangular CBPM is designed for it has better X-Y isolation than a cylinder one. It has been simulated and measured, and the results agree with each other very well. The procedures and results for the simulation and the cold test will be shown later and it will be proved that this is a reliable method for the CBPM design.
      PCAS:
  • 加载中
  • [1] Slaton T et al. Development of Nanometer Resolution C-band Radio Frequency Beam Position Monitors in the Final Focus Test Beam. LINAC'98, Chicago. KEK Preprint, Aug. 1998. 98-145[2] Shintake T. Development of Nanometer Resolution RF-BPM. KEK Preprint, November 1998. 98-188[3] Balakin V et al. Experimental Results From a Microwave Cavity Beam Position Monitor. Proceedings of the 1999 Particle Accelerator Conference. New York. 1999[4] Johnson R et al. Cavity BPMs for the NLC. SLAC-PUB-9211, May 2002[5] LI Zeng-Hai et al. Cavity BPM with Dipole-mode-selective Coupler. Proceedings of the 2003 Particle Accelerator Conference. 2003[6] Walston S et al. Nuclear Instruments and Methods in Physics Research A, 2007, 578: 1-22[7] Walston S et al. Resolution of a High Performance Cavity Beam Position Monitor System. Proceedings PAC. 2007[8] CHU Jian-Hua. Development of a C-Band Cavity BPM and RF Electronics (Doctoral Thesis). Shanghai: Shanghai Institute of Applied Physics, 2008 (in Chinese)[9] LI Xiang. Design and Experiments for Cavity Beam Position Monitor (Master Thesis). Department of Engineering Physics, Tsinghua University, May, 2009[10] Yoichi Inoue et al. Physical Review Special Topics-Accelerators and Beams, 2008, 11: 062801[11] TANG Chuan-Xiang et al. Nuclear Instruments and Methods in Physics Research A, 2009, 608: S70-S74[12] Tomoya Nakamura. Development of Beam-position Monitors with High Position Resolution (Master Thesis). Department of Physics, Graduate School of Science, The University of Tokyo, Feb. 3, 2008[13] HE Xiao-Zhong. Theoratical and Initial Experimental Research on Low Emittance Photoinjector (Doctor Thesis). Department of Engineering Physics, Tsinghua University, June, 2006
  • 加载中

Get Citation
SU Jia-Hang, DU Ying-Chao, HUA Jian-Fei, ZHENG Shu-Xin, QIU Jia-Qi, YANG Jin, HUANG Wen-Hui, CHEN Huai-Bi and TANG Chuan-Xiang. Design and cold test of a rectangular cavity beam position monitor[J]. Chinese Physics C, 2013, 37(1): 017002. doi: 10.1088/1674-1137/37/1/017002
SU Jia-Hang, DU Ying-Chao, HUA Jian-Fei, ZHENG Shu-Xin, QIU Jia-Qi, YANG Jin, HUANG Wen-Hui, CHEN Huai-Bi and TANG Chuan-Xiang. Design and cold test of a rectangular cavity beam position monitor[J]. Chinese Physics C, 2013, 37(1): 017002.  doi: 10.1088/1674-1137/37/1/017002 shu
Milestone
Received: 2012-03-02
Revised: 1900-01-01
Article Metric

Article Views(3153)
PDF Downloads(285)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Design and cold test of a rectangular cavity beam position monitor

    Corresponding author: SU Jia-Hang,

Abstract: CBPM is a kind of monitor which is used for the measurement of beam transverse position. And it is more and more popular for its high potential in the resolution performance. In theory, the resolution can reach about 1 nanometer. In this paper, a rectangular CBPM is designed for it has better X-Y isolation than a cylinder one. It has been simulated and measured, and the results agree with each other very well. The procedures and results for the simulation and the cold test will be shown later and it will be proved that this is a reliable method for the CBPM design.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return