Study of eddy current power loss in an RCS vacuum chamber

  • In a Rapid Cycling Synchrotron (RCS), power loss due to an eddy current on the metal vacuum chamber would cause heating of the vacuum chamber. It is important to study the effect for estimating eddy current induced power loss and temperature growth. Analytical formulas for eddy current power loss for various types of vacuum chambers are derived for dipole and quadrupole repectively. By using the prototype of dipole of CSNS/RCS, an experiment was done to test the analytical formula. The derived formulas were applied to calculating the eddy current power loss on some special structures of an RCS vacuum chamber.
      PCAS:
  • 加载中
  • [1] WANG S et al. Chinese Physics C (HEP NP), 2009,33(S2): 1-32 Bennett J, Elsey R, Dossett A. Vacuum, 1978, 28: 507-5093 Kinsho M et al. Vacuum, 2004, 73: 187-1934 Horikoshi G et al. Vacuum System for the KEK ProtonSynchrotron, PAC19775 Gardner C et al. Conceptual Design of the RCMS, BNL.20036 Lee Y Y. Estimate of Eddy Current Power Loss in theDipole Vacuum Chamber, Booster Technical Note 51,Brookhaven National Laboratory. 19867 Lee S Y. Nuclear Instruments and Methods in Physics Re-search A, 1991, 300: 151-1588 Conceptual Design Report of Energy Modulation Ion Ther-apy Facility. IHEP-Report, May, 20089 HUANG S Y, PU S Z. Heat and Mass Transfer, 1995, 30:411-41510 YANG S M, TAO W S. Heat Transfer Theory, Higher Ed-ucation Press of China. 1998
  • 加载中

Get Citation
XU Shou-Yan and WANG Sheng. Study of eddy current power loss in an RCS vacuum chamber[J]. Chinese Physics C, 2012, 36(2): 160-166. doi: 10.1088/1674-1137/36/2/011
XU Shou-Yan and WANG Sheng. Study of eddy current power loss in an RCS vacuum chamber[J]. Chinese Physics C, 2012, 36(2): 160-166.  doi: 10.1088/1674-1137/36/2/011 shu
Milestone
Received: 2011-05-18
Revised: 2011-05-24
Article Metric

Article Views(4167)
PDF Downloads(444)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Study of eddy current power loss in an RCS vacuum chamber

    Corresponding author: WANG Sheng,

Abstract: In a Rapid Cycling Synchrotron (RCS), power loss due to an eddy current on the metal vacuum chamber would cause heating of the vacuum chamber. It is important to study the effect for estimating eddy current induced power loss and temperature growth. Analytical formulas for eddy current power loss for various types of vacuum chambers are derived for dipole and quadrupole repectively. By using the prototype of dipole of CSNS/RCS, an experiment was done to test the analytical formula. The derived formulas were applied to calculating the eddy current power loss on some special structures of an RCS vacuum chamber.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return