Fluence rate linear response limit of a scintillators to γ-rays

  • Scintillation detectors based on LSO, CeF and PbWO are the main candidates for measuring γ-rays in a mixed γ/n pulsed radiation field with high intensity. An experiment using the Lissajous figure method to study the high fluence rate response behavior of three kinds of commonly used scintillators is introduced in this paper. The result shows that the fluence rate linear response limit of LSO and CeF is 1.9×1019 and 2.1×1018MeV/(cm2·s), respectively, and the PbWO scintillator still maintains linear response when the fluence rate of γ-ray is up to 2.0 × 1020 MeV/(cm2·s).
      PCAS:
  • 加载中
  • [1] Carel W.E. van Eijk. Nuclear Instruments and Methods in Physics Research A, 2001, 460: 1-142 Marvin J. Weber. Journal of Luminescence, 2002, 100: 35-453 Lempicki A, Glodo J. Nuclear Instruments and Methods in Physics Research A, 1998, 416: 333-3444 Charles L Melcher, Merry A Spurrier, Lars Eriksson et al. IEEE Trans. Nucl. Sci., 2003, 50: 762-7665 Ludziejewski T, Moszynska K, Moszynski M et al. IEEE Trans. Nucl. Sci., 1995, 42: 328-3366 Anderson D F. IEEE Trans. Nucl. Sci., 1989, 36: 137-1407 Moses W W, Dernenzo S E. IEEE Trans. Nucl. Sci., 1989, 36: 173-1768 Baccaro S, Borgia B, Cecilia A et al. Nuclear Physics B, 1998, 61: 66-709 Zorenkoa Yu, Voloshinovskiib A, Moroza Z et al. Radiation Measurements, 2004, 38: 397-40110 QIN Lai-Shun, REN Guo-Hao et al. Journal of Synthetic Crystals, 2003, 32(4)μ286-294 (in Chinese)11 SONG Zhao-hui, WANG Kui-Lu et al. Measurement Sci- ence and Technology, 2005, 16: 1312-131512 Dorenbos P, Haas J T M de, Eijk C W E van et al. IEEE Trans. Nucl. Sci., 1994, 41: 735-73713 Glenn F. Knoll. Radiation Detection and Measurement (3rd Edition). New York: John Wiley Sons, Inc., 1999, 225
  • 加载中

Get Citation
GUAN Xing-Yin, SONG Zhao-Hui and HAN He-Tong. Fluence rate linear response limit of a scintillators to γ-rays[J]. Chinese Physics C, 2011, 35(7): 656-659. doi: 10.1088/1674-1137/35/7/010
GUAN Xing-Yin, SONG Zhao-Hui and HAN He-Tong. Fluence rate linear response limit of a scintillators to γ-rays[J]. Chinese Physics C, 2011, 35(7): 656-659.  doi: 10.1088/1674-1137/35/7/010 shu
Milestone
Received: 2010-09-25
Revised: 2010-11-08
Article Metric

Article Views(3946)
PDF Downloads(387)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Fluence rate linear response limit of a scintillators to γ-rays

Abstract: Scintillation detectors based on LSO, CeF and PbWO are the main candidates for measuring γ-rays in a mixed γ/n pulsed radiation field with high intensity. An experiment using the Lissajous figure method to study the high fluence rate response behavior of three kinds of commonly used scintillators is introduced in this paper. The result shows that the fluence rate linear response limit of LSO and CeF is 1.9×1019 and 2.1×1018MeV/(cm2·s), respectively, and the PbWO scintillator still maintains linear response when the fluence rate of γ-ray is up to 2.0 × 1020 MeV/(cm2·s).

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return