Design studies on a 500 kV DC gun photo-injector for the BXERL test facility

  • BXERL is a proposal for a test facility (Beijing X-ray Energy Recovery Linac), which requires its injector to provide an electron beam of 5 MeV, 77 pC/ bunch at a repetition rate of 130 MHz (average current of 10 mA). In this paper, we present the design of the injector, which consists of a 500 kV photocathode DC gun equipped with a GaAs cathode preparation device, a 1.3 GHz normal conducting RF buncher, two solenoids, and one cryomodule containing two 1.3 GHz 2-cell superconducting RF cavities as the energy booster. The detailed beam dynamics show that the injector can generate electron bunches with a RMS normalized emittance of 1.49 πmm·mrad, a bunch length of 0.67 mm, a beam energy of 5 MeV and an energy spread of 0.72%.
      PCAS:
  • 加载中
  • [1] Neil G R et al. Phys. Rev. Lett., 2000, 84: 6622 Hajima R et al. First Demonstration of Energy-Recovery Operation in the JAERI supper conducting Linac for a High-Power Free-Electron Laser, Proceedings of FEL2002, USA, 1153 Antokhin E A et al. Nucl. Instrum. Methods A, 2004, 528: 154 Ben-Zvi I. The ERL High-Energy Cooler for RHIC, Proceedings of EPAC06, Scotland, 9405 Derbenev Y S et al. Proceedings of EPAC04, Switzerland, 8936 Gruner S M et al. Rev. Sci. Instrum., 2002, 73: 14027 Baptiste K et al. Nucl. Instrum. Methods A, 2009, 599: 98 Overview of the present status of the SRF gun design and construction, CARE Note-2004-010-ELAN, Germany9 Ben-Zvi I et al. Nucl. Instrum. Methods A, 2006, 557: 33710 McKenzie J W et al. Injector design for the 4GLS high average current loop, Proceedings of PAC07, USA, 110011 Ivan V Bazarov et al. Phys. Rev. ST Accel. Beams, 2005, 8: 03420212 LIU H et al. Nucl. Instrum. Methods A, 1995, 358: 475
  • 加载中

Get Citation
LIU Sheng-Guang and XU Jin-Qiang. Design studies on a 500 kV DC gun photo-injector for the BXERL test facility[J]. Chinese Physics C, 2011, 35(1): 88-91. doi: 10.1088/1674-1137/35/1/018
LIU Sheng-Guang and XU Jin-Qiang. Design studies on a 500 kV DC gun photo-injector for the BXERL test facility[J]. Chinese Physics C, 2011, 35(1): 88-91.  doi: 10.1088/1674-1137/35/1/018 shu
Milestone
Received: 2010-04-24
Revised: 2010-06-01
Article Metric

Article Views(3908)
PDF Downloads(537)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Design studies on a 500 kV DC gun photo-injector for the BXERL test facility

Abstract: BXERL is a proposal for a test facility (Beijing X-ray Energy Recovery Linac), which requires its injector to provide an electron beam of 5 MeV, 77 pC/ bunch at a repetition rate of 130 MHz (average current of 10 mA). In this paper, we present the design of the injector, which consists of a 500 kV photocathode DC gun equipped with a GaAs cathode preparation device, a 1.3 GHz normal conducting RF buncher, two solenoids, and one cryomodule containing two 1.3 GHz 2-cell superconducting RF cavities as the energy booster. The detailed beam dynamics show that the injector can generate electron bunches with a RMS normalized emittance of 1.49 πmm·mrad, a bunch length of 0.67 mm, a beam energy of 5 MeV and an energy spread of 0.72%.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return