Absorption Correlation in Pion Interferometry Analyses

  • The effect of absorption correlation on the analyzed results of pion interferometry is studied. The way to remove this effect is discussed by using the data from VUU simulation. The data for collisions of 1.8A GeV Ar+Pb at the Bevalac streamer chamber are analyzed. The spatial parameter of the source extracted from pion interferometry is less than the true value due to the absorption correlation. The effect of absorption correlation can be eliminated by properly constructing the background.
  • 加载中
  • [1] M.Gyulassy,S.K.Kauffmann and L.W.Wilson,Phys.Rev,C20(1979)2267.[2]W.A.Zajc et al,Phys.Rev.C29(1984)2173.[3]D.Beavis et al,Phys.Rev,C34(1986)757.[4]刘亦铭等,高能物理核物理,15(199)123;Y.Z.Jiang et al,Phys.Rev,C44(1991)1957.[5]D.H.Boal,C.K.Gelbke and B.K.Jennings,Rev.Mod.Phys,62(1990)553;D.L'Hote,Nucl.Phys,A545(1992)381.[6]Y.M.Liu et al.,Phys.Rev,C34(1986)1667;刘亦铭,核物理动态,6(1989)30.[7]D.Keane et al.“Colletive flow of pions produced in nucleus-nucleus collisions”,in Proc.of the Nuclear Dynamics Workshop IV,Cooper Mountain,Colorado,p.151(1986).[8]王山等,高能物理与核物理,17(1993)533.[9]B.A.Li,w.Bauer.and G.F.Bertsch,Phys.Rev.,C44(1991)2095;J.P.Alard et al.,Rapport DPh-N/Saclay n02583B,“Anisotropy of the pion emission in relativistic nucleus-nucleus collisions”,DPHN90-4(1990).[10]M.Gyulassy,Phys.Rev.Lett,48(1982)454.[11]H.Kruse,B.V.Jacak,and H.Stockeer,Phys.Rev.Lett.,54(1985)289,J.J.Molitoris,and H.Stocker,Phys.Lett,162B(1985)47;J.J Molitoris et al,Phys.Rev,C37(1988)1014.[12]T.J.Humanic,Phys.Rev,C34(1986)191.[13]P.Danielewicz and G.Odyniecl,Phys.Lett,157B(1985)146.[14]Y.M.Liu et al.,“Pion correlation in Ar on Pb collisions at 1.8GeV/nucleon”,Proc.of international workshop on quark-gluon structure of hadrons and nuclei,p.201,edited by Kisslinger L.S. and Qiu Xijun,Shanghai,(1990).[15]S.Wang et al,Phys.Rev.,C44(1991)1091;王山等,高能物理与核物理,14(1990)907.
  • 加载中

Get Citation
Huo Lei, Zhang Weining, Wang Shan and Liu Yiming. Absorption Correlation in Pion Interferometry Analyses[J]. Chinese Physics C, 1994, 18(7): 630-636.
Huo Lei, Zhang Weining, Wang Shan and Liu Yiming. Absorption Correlation in Pion Interferometry Analyses[J]. Chinese Physics C, 1994, 18(7): 630-636. shu
Milestone
Received: 1900-01-01
Revised: 1900-01-01
Article Metric

Article Views(2774)
PDF Downloads(545)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Absorption Correlation in Pion Interferometry Analyses

    Corresponding author: Huo Lei,
  • Department of Physics, Harbin Institute of Technology, Harbin 1500011 Department of Physics, Kent State University, Kent, Ohio 442422 Department of Physics, Univertsity of California, Riverside, CA 92521

Abstract: The effect of absorption correlation on the analyzed results of pion interferometry is studied. The way to remove this effect is discussed by using the data from VUU simulation. The data for collisions of 1.8A GeV Ar+Pb at the Bevalac streamer chamber are analyzed. The spatial parameter of the source extracted from pion interferometry is less than the true value due to the absorption correlation. The effect of absorption correlation can be eliminated by properly constructing the background.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return