ICI Detector for Measuring Gamma-Ray Fluxes in Mixed Gamma-Neutron Fields

  • A new gamma-ray detecting device called ICI detector has been developed and tested. Like vacuum Compton diode(VCD) and dielectric Compton diode(DCD) generally used in pulsed gamma-ray measurements, ICI detector operates by utilization of the Compton effect and has low sensitivity to gamma-ray fluxes, very fast time response, large linearity and wide dynamic range, it is desired for using the device to measure intense and rapidly changing gamma-ray fluxes. Compared to the existing VCDs and DCDs, the detector requires no vacuum in operation and the active volume is only 2mm thick.
  • [1] . LIU Zhao-Qing et al. Pulse radiation Measurement. Bei-jing: Science Press, 1994. 186-196(in Chinese)(刘兆庆等.脉冲辐射场诊断技术.北京:科学出版社,1994.186-196)2. NI Yuan-Xing. Pulse Radiation Measurement and Diagno-sis. Xi'an: Northwest Institute of Nuclear Technology, 1997.64-77(in Chinese)(倪源兴.脉冲射线测量和诊断技术.西安:西北核技术研究所1997. 64-77)3. Ebert P J, Lauzon A F. Vacuum Diode Detector for Measuring High Intensity Gamma-Ray Flux. Rev. Sci. Instr.,1967, 38(12): 1747-7524. Fewell T R. Compton Diodes: Theory and Development for Radiation Detectors: SC-DR-720118. 19725. Knoll G F. Radition Detection and Measurement [M]. New York: John Wiley Sons, Inc., 20006. Stevens J. Design and Characterization of an Absolute Gamma-Ray Intensity Detection: EGG1183-2288. 19727. Artuso J, Stevens J. Linearity, Time Domain Reflector Me-ter and Fourier Analysis Studies of an Evacuated Compton Detector: EGG 1183?277. 19718. Ebert P J, Lauzon A F. IEEE Trans. Nucl. Sci., 1966, NS-13(2): 735-7419. Briesmeister J B. MCNP-A General Monte Carlo N-Particle Transport code: LA-12625-M-Manual. 199710. OUYANG X P, LI Z F, WANG Q S et al. HEP NP, 2005,29(4): 399-403(in Chinese)(欧阳晓平,李真富,王群书等.高能物理与核物理,2005,29(4): 399-403)11. OUYANG X P, LI Z F, HUO Y K et al. HEP NP, 2001,25(11): 1100-1105(in Chinese)(欧阳晓平,李真富,霍裕昆等.高能物理与核物理,2001,25(11): 1100-1105)12. OUYANG X P, LI Z F, WANG Q S et al. Acta Physica Sinica, 2005, 54(10): 4643-6647(in Chinese)(欧阳晓平,李真富,王群书等.物理学报,2005, 54(10):4643-4647)
  • [1] . LIU Zhao-Qing et al. Pulse radiation Measurement. Bei-jing: Science Press, 1994. 186-196(in Chinese)(刘兆庆等.脉冲辐射场诊断技术.北京:科学出版社,1994.186-196)2. NI Yuan-Xing. Pulse Radiation Measurement and Diagno-sis. Xi'an: Northwest Institute of Nuclear Technology, 1997.64-77(in Chinese)(倪源兴.脉冲射线测量和诊断技术.西安:西北核技术研究所1997. 64-77)3. Ebert P J, Lauzon A F. Vacuum Diode Detector for Measuring High Intensity Gamma-Ray Flux. Rev. Sci. Instr.,1967, 38(12): 1747-7524. Fewell T R. Compton Diodes: Theory and Development for Radiation Detectors: SC-DR-720118. 19725. Knoll G F. Radition Detection and Measurement [M]. New York: John Wiley Sons, Inc., 20006. Stevens J. Design and Characterization of an Absolute Gamma-Ray Intensity Detection: EGG1183-2288. 19727. Artuso J, Stevens J. Linearity, Time Domain Reflector Me-ter and Fourier Analysis Studies of an Evacuated Compton Detector: EGG 1183?277. 19718. Ebert P J, Lauzon A F. IEEE Trans. Nucl. Sci., 1966, NS-13(2): 735-7419. Briesmeister J B. MCNP-A General Monte Carlo N-Particle Transport code: LA-12625-M-Manual. 199710. OUYANG X P, LI Z F, WANG Q S et al. HEP NP, 2005,29(4): 399-403(in Chinese)(欧阳晓平,李真富,王群书等.高能物理与核物理,2005,29(4): 399-403)11. OUYANG X P, LI Z F, HUO Y K et al. HEP NP, 2001,25(11): 1100-1105(in Chinese)(欧阳晓平,李真富,霍裕昆等.高能物理与核物理,2001,25(11): 1100-1105)12. OUYANG X P, LI Z F, WANG Q S et al. Acta Physica Sinica, 2005, 54(10): 4643-6647(in Chinese)(欧阳晓平,李真富,王群书等.物理学报,2005, 54(10):4643-4647)
  • 加载中

Get Citation
OUYANG Xiao-Ping, ZHANG Zhong-Bing, WANG Qiu-Shu and WANG Wei. ICI Detector for Measuring Gamma-Ray Fluxes in Mixed Gamma-Neutron Fields[J]. Chinese Physics C, 2006, 30(3): 228-231.
OUYANG Xiao-Ping, ZHANG Zhong-Bing, WANG Qiu-Shu and WANG Wei. ICI Detector for Measuring Gamma-Ray Fluxes in Mixed Gamma-Neutron Fields[J]. Chinese Physics C, 2006, 30(3): 228-231. shu
Milestone
Received: 2005-06-09
Revised: 1900-01-01
Article Metric

Article Views(3420)
PDF Downloads(617)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

ICI Detector for Measuring Gamma-Ray Fluxes in Mixed Gamma-Neutron Fields

    Corresponding author: ZHANG Zhong-Bing,
  • Department of Engineering Physics, Tsinghua University, Beijing 100084, China2 Northwest Institute of Nuclear Technology, Xi'an 710024, China

Abstract: A new gamma-ray detecting device called ICI detector has been developed and tested. Like vacuum Compton diode(VCD) and dielectric Compton diode(DCD) generally used in pulsed gamma-ray measurements, ICI detector operates by utilization of the Compton effect and has low sensitivity to gamma-ray fluxes, very fast time response, large linearity and wide dynamic range, it is desired for using the device to measure intense and rapidly changing gamma-ray fluxes. Compared to the existing VCDs and DCDs, the detector requires no vacuum in operation and the active volume is only 2mm thick.