Intelligent low-level RF system by non-destructive beam monitoring device for cyclotrons

Cited by

1. Silakhuddin, S., Darmawan, R.S., Dwiatmaja, A. et al. Calculation methods of RF power requirement on an RF dee cavity of cyclotron[J]. International Journal of Power Electronics and Drive Systems, 2023, 14(3): 1553-1561. doi: 10.11591/ijpeds.v14.i3.pp1553-1561
2. Asadi, M.S.S., Afarideh, H., Ghergherechi, M. et al. Model Predictive Control-Based Smart Linear Servo-Motor Driver for a Resonance Frequency Tuner of Azimuth Variable Field Cyclotrons[J]. Journal of the Korean Physical Society, 2020, 76(7): 592-594. doi: 10.3938/jkps.76.592
3. Qin, D.. Data Monitoring Platform for Submarine Cable Tunnel Operation Based on Data Mining[J]. Journal of Coastal Research, 2019, 93(sp1): 960-968. doi: 10.2112/SI93-139.1
4. Min, S.-H., Jung, I.S., Park, C. et al. Low Level RF Control of Cyclotron for Neutron Capture Therapy System[J]. 2019. doi: 10.1109/IVEC.2019.8745340
Get Citation
Sharifi Asadi Malafeh, M. Ghergherehchi, H. Afarideh, J. S. Chai and Yoon Sang Kim. Intelligent low-level RF system by non-destructive beam monitoring device for cyclotrons[J]. Chinese Physics C, 2016, 40(4): 047001. doi: 10.1088/1674-1137/40/4/047001
Sharifi Asadi Malafeh, M. Ghergherehchi, H. Afarideh, J. S. Chai and Yoon Sang Kim. Intelligent low-level RF system by non-destructive beam monitoring device for cyclotrons[J]. Chinese Physics C, 2016, 40(4): 047001.  doi: 10.1088/1674-1137/40/4/047001 shu
Milestone
Received: 2015-09-14
Article Metric

Article Views(1829)
PDF Downloads(293)
Cited by(4)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Intelligent low-level RF system by non-destructive beam monitoring device for cyclotrons

Abstract: The project of a 10 MeV PET cyclotron accelerator for medical diagnosis and treatment was started at Amirkabir University of Technology in 2012. The low-level RF system of the cyclotron accelerator is designed to stabilize acceleration voltage and control the resonance frequency of the cavity. In this work an Intelligent Low Level Radio Frequency Circuit or ILLRF, suitable for most AVF cyclotron accelerators, is designed using a beam monitoring device and narrow band tunable band-pass filter. In this design, the RF phase detection does not need signal processing by a microcontroller.