Performance analysis of quantitative phase retrieval method in Zernike phase contrast X-ray microscopy

  • Since the invention of Zernike phase contrast method in 1930, it has been widely used in optical microscopy and more recently in X-ray microscopy. Considering the image contrast is a mixture of absorption and phase information, we recently have proposed and demonstrated a method for quantitative phase retrieval in Zernike phase contrast X-ray microscopy. In this contribution, we analyze the performance of this method at different photon energies. Intensity images of PMMA samples are simulated at 2.5 keV and 6.2 keV, respectively, and phase retrieval is performed using the proposed method. The results demonstrate that the proposed phase retrieval method is applicable over a wide energy range. For weakly absorbing features, the optimal photon energy is 2.5 keV, from the point of view of image contrast and accuracy of phase retrieval. On the other hand, in the case of strong absorption objects, a higher photon energy is preferred to reduce the error of phase retrieval. These results can be used as guidelines to perform quantitative phase retrieval in Zernike phase contrast X-ray microscopy with the proposed method.
      PCAS:
  • 加载中
  • [1] F. Zernike, Physica, 9 (10): 974-986 (1942)
    [2] G. Schmahl, D. Rudolph, P. Guttmann et al, Rev. Sci. Instrum., 66 (2): 1282-1286 (1995)
    [3] C. Holzner, M. Feser, S. Vogt et al, Nat. Phys., 6 (11): 883-887 (2010)
    [4] M. Stampanoni, R. Mokso, F. Marone et al, Phys. Rev. B, 81 (14): 140105 (2010)
    [5] D. Wang, N. Li, Z. Wang et al, J. Synchrotron Rad., 21 (5): 1175-1179 (2014)
    [6] M. Awaji, Y. Suzuki, A. Takeuchi et al, J. Synchrotron Rad., 9 (3): 125-127 (2002)
    [7] H. S. Youn and S. W. Jung, J. Microsc., 223 (1): 53-56 (2006)
    [8] A. Tkachuk, F. Duewer, H. Cui et al, Z. Kristallogr., 222 (11): 650-655 (2007)
    [9] Y. Liu, J. C. Andrews, J. Wang et al, Opt. Express, 19(2): 540-545 (2011)
    [10] Q. Yuan, K. Zhang, Y. Hong et al, J. Synchrotron Rad., 19 (6): 1021-1028 (2012)
    [11] Z. Wang, K. Gao, J. Chen et al, Biotechnol. Adv., 31 (3): 387-392 (2013)
    [12] I. Vartiainen, M. Warmer, D. Goeries et al, J. Synchrotron Rad., 21 (4): 790-794 (2014)
    [13] Y. Yang, R. Heine, Y. Cheng et al, Appl. Phys. Lett., 105 (9): 094101 (2014)
    [14] Y. T. Chen, T. Y. Chen, J. Yi et al, Opt. Lett., 36 (7): 1269-1271 (2011)
    [15] I. Vartiainen, R. Mokso, M. Stampanoni et al, Opt. Lett., 39 (6): 1601-1604 (2014)
    [16] T. Y. Chen, Y. T. Chen, C. L. Wang et al, Opt. Express, 19 (21): 19919-19924 (2011)
    [17] G. C. Yin, F. R. Chen, Y. Hwu et al, Appl. Phys. Lett., 90 (18): 181118 (2007)
    [18] H. Chen, Z. Wang, K. Gao et al, J. Synchrotron Rad., 22 (4): 1056-1061 (2015)
  • 加载中

Get Citation
Heng Chen, Kun Gao, Da-Jiang Wang, Li Song and Zhi-Li Wang. Performance analysis of quantitative phase retrieval method in Zernike phase contrast X-ray microscopy[J]. Chinese Physics C, 2016, 40(2): 029001. doi: 10.1088/1674-1137/40/2/029001
Heng Chen, Kun Gao, Da-Jiang Wang, Li Song and Zhi-Li Wang. Performance analysis of quantitative phase retrieval method in Zernike phase contrast X-ray microscopy[J]. Chinese Physics C, 2016, 40(2): 029001.  doi: 10.1088/1674-1137/40/2/029001 shu
Milestone
Received: 2015-04-29
Revised: 2015-08-26
Fund

    Supported by the State Key Project for Fundamental Research (2012CB825801), National Natural Science Foundation of China (11475170, 11205157 and 11179004) and Anhui Provincial Natural Science Foundation (1508085MA20)

Article Metric

Article Views(1226)
PDF Downloads(343)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Performance analysis of quantitative phase retrieval method in Zernike phase contrast X-ray microscopy

    Corresponding author: Zhi-Li Wang,
  • 1. Department of Physics, University of Science and Technology of China, Hefei 230026, China
  • 2. National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China
  • 3.  National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China
Fund Project:  Supported by the State Key Project for Fundamental Research (2012CB825801), National Natural Science Foundation of China (11475170, 11205157 and 11179004) and Anhui Provincial Natural Science Foundation (1508085MA20)

Abstract: Since the invention of Zernike phase contrast method in 1930, it has been widely used in optical microscopy and more recently in X-ray microscopy. Considering the image contrast is a mixture of absorption and phase information, we recently have proposed and demonstrated a method for quantitative phase retrieval in Zernike phase contrast X-ray microscopy. In this contribution, we analyze the performance of this method at different photon energies. Intensity images of PMMA samples are simulated at 2.5 keV and 6.2 keV, respectively, and phase retrieval is performed using the proposed method. The results demonstrate that the proposed phase retrieval method is applicable over a wide energy range. For weakly absorbing features, the optimal photon energy is 2.5 keV, from the point of view of image contrast and accuracy of phase retrieval. On the other hand, in the case of strong absorption objects, a higher photon energy is preferred to reduce the error of phase retrieval. These results can be used as guidelines to perform quantitative phase retrieval in Zernike phase contrast X-ray microscopy with the proposed method.

    HTML

Reference (18)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return