An X-ray imaging device based on a GEM detector with delay-line readout

Get Citation
ZHOU Yi, LI Cheng, SUN Yong-Jie and SHAO Ming. An X-ray imaging device based on a GEM detector with delay-line readout[J]. Chinese Physics C, 2010, 34(1): 78-82. doi: 10.1088/1674-1137/34/1/014
ZHOU Yi, LI Cheng, SUN Yong-Jie and SHAO Ming. An X-ray imaging device based on a GEM detector with delay-line readout[J]. Chinese Physics C, 2010, 34(1): 78-82.  doi: 10.1088/1674-1137/34/1/014 shu
Milestone
Received: 2008-12-04
Revised: 2008-12-31
Article Metric

Article Views(2776)
PDF Downloads(637)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

An X-ray imaging device based on a GEM detector with delay-line readout

    Corresponding author: LI Cheng,

Abstract: 

An X-ray imaging device based on a triple-GEM (Gas Electron Multiplier) detector, a fast delay-line circuit with 700 MHz cut-off frequency and two dimensional readout strips with 150 μm width on the top and 250 μm width on the bottom, is designed and tested. The localization information is derived from the propagation time of the induced signals on the readout strips. This device has a good spatial resolution of 150 μm and works stably at an intensity of 105 Hz/mm2 with 8~keV X-rays.